
【国外标准】 Standard Guide for Sensory Evaluation of Axillary Deodorancy
本网站 发布时间:
2024-02-28
开通会员免费在线看70000余条国内标准,赠送文本下载次数,单本最低仅合13.3元!还可享标准出版进度查询、定制跟踪推送、标准查新等超多特权!  
查看详情>>

适用范围:
5.1 The procedures recommended in this practice can be used to clinically assess axillary deodorant efficacy of personal care products.5.2 This practice is applicable to the product categories which include deodorant and toilet soap bars, liquid bath soaps and gels, deodorant sticks, antiperspirants, creams and lotions, body talcs, and aerosol and pump delivery deodorants, antiperspirants, and body colognes.5.3 Procedures of the type described herein may be used to aid in the communication of efficacy within and between manufacturers and to the consumer through the various public communications media. Guidelines are suggested due to the need to determine the relative or absolute performance of experimental materials or of commercial products.5.4 These procedures may be used by persons who have familiarized themselves with these procedures and have had previous experience with sensory evaluation.5.5 This practice provides suggested procedures and is not meant to exclude alternate procedures which may be effectively used to provide the same clinical result.1.1 This guide provides procedures which may be used in the design and analysis of studies to quantitatively assess the intensity of human axillary odor for the purpose of substantiating deodorant efficacy of personal care products.1.2 This guide includes protocols for the selection and training of assessors, selection of subjects, experimental design, and statistical analyses. This practice is limited to assessment of axillary odor by trained assessors. Self-evaluation protocols are valid for selected sensory tasks but may be less sensitive.1.3 With respect to the source of axillary odor, three groups of secretory glands are present in the axillae which participate to a greater or lesser extent in its production—eccrine, apocrine, and sebaceous. Axillary odor has been primarily ascribed to the apocrine gland secretion (1) .2 Body odor intensity has been correlated with the volume of the secretory portion of the apocrine gland (2) and the density of the glands.1.3.1 Apocrine glands are found primarily in the axillary vault in conjunction with axillary hairs (3). Pure apocrine sweat is sterile and odorless and axillary odor results from degradation of apocrine sweat by resident skin bacteria (4). High bacterial populations are found in moist regions of the body, especially in the axillae, providing the appropriate environment for growth (5).1.3.2 Eccrine glands keep the axillae moist through thermally and emotionally induced secretions (6).1.3.3 The sebaceous glands excrete higher molecular weight lipid materials which absorb and retain the volatile materials resulting from bacterial action (7) . The aerobic diphtheroids are able to produce the typical acrid axillary odor and the micrococcaceae produce an isovaleric acid-like odor when incubated with apocrine sweat (8). Therefore, the most undesirable component of axillary odor is caused by degradation of apocrine sweat by particular bacteria normally found in the axillary vault.1.4 Personal care products are sold and used primarily for their ability to reduce the perception of body odor not only by the individual using the product but also by individuals within the scope of contact. Deodorant protection may be achieved by these products through various modes of action. Antiperspirants achieve their primary efficacy by means of the action of inorganic salts on the eccrine gland production of sweat. Antimicrobial agents achieve deodorancy by inhibiting the growth and activity of the microflora in the axillary vault thus reducing the microbial decomposition of sweat and the consequent production of body odor. Absorbents function either by “binding” available moisture or malodorous substances. Fragrances are effective by altering the perception of malodor and increasing the degree of “pleasantness.” Other modes of control become important from time to time, representing changes in the state-of-the-art in product development.1.5 The studies discussed herein are interpreted through the use of statistical tests of hypotheses. These hypotheses are usually of the form:The Deodorant Efficacy of Treatment A= The Deodorant Efficacy of Treatment B1.5.1 It should be noted that failure to reject this hypothesis at a specified level of significance does not prove the hypothesis, but merely that the weight of evidence provided by the experiment is not sufficient to reject the hypothesis. This could occur because either: a) The hypothesis is close to truth and great experimental power would be required to reject it, or b) The experiment by design was low in power and, therefore, incapable of rejecting the hypothesis; even when it is far from true. This can occur due to design structure or low sample size. These facts must be taken into consideration when interpreting study results.1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
标准号:
ASTM E1207-14(2022)
标准名称:
Standard Guide for Sensory Evaluation of Axillary Deodorancy
英文名称:
Standard Guide for Sensory Evaluation of Axillary Deodorancy标准状态:
Active-
发布日期:
-
实施日期:
出版语种:
- 推荐标准
- ASTM F3258-23 Standard Specification for Protectors for Rubber Insulating Gloves Meeting Specific Performance Requirements
- ASTM F3259-17 Standard Guide for Micro-computed Tomography of Tissue Engineered Scaffolds
- ASTM F3260-18 Standard Test Method for Determining the Flexural Stiffness of Medical Textiles
- ASTM F3262-17 Standard Classification System for Small Unmanned Aircraft Systems (sUASs) for Land Search and Rescue
- ASTM F3265-17(2023) Standard Test Method for Grid-Video Obstacle Measurement
- ASTM F3268-18a Standard Guide for in vitro Degradation Testing of Absorbable Metals
- ASTM F3270/F3270M-17 Standard Practice for Compression versus Load Properties of Gasket Materials
- ASTM F3273-17(2021)e1 Standard Specification for Wrought Molybdenum-47.5 Rhenium Alloy for Surgical Implants (UNS R03700)
- ASTM F3275-22 Standard Guide for Using a Force Tester to Evaluate Performance of a Brush Part Designed to Clean the Internal Channel of a Medical Device
- ASTM F3276-22 Standard Guide for Using a Force Tester to Evaluate the Performance of a Brush Part Designed to Clean the External Surface of a Medical Device
- ASTM F3277-19 Standard Specification for Cantilevered Steel Bunks Used in Detention and Correctional Facilities
- ASTM F3283/F3283M-18 Standard Specification for the Manufacturing of High-Voltage Proximity Alarm to be used for the Detection of Overhead High Voltage Alternating Current (AC)
- ASTM F3288/F3288M-20 Standard Specification for MRS-Rated Metric- and Inch-sized Crosslinked Polyethylene (PEX) Pressure Pipe
- ASTM F3292-19 Standard Practice for Inspection of Spinal Implants Undergoing Testing
- ASTM F3293-18 Standard Guide for Application of Test Soils for the Validation of Cleaning Methods for Reusable Medical Devices