
【国外标准】 Standard Test Method for Performance of Open Vat Fryers
本网站 发布时间:
2024-02-28
开通会员免费在线看70000余条国内标准,赠送文本下载次数,单本最低仅合13.3元!还可享标准出版进度查询、定制跟踪推送、标准查新等超多特权!  
查看详情>>

适用范围:
5.1 The measured energy input rate test is used to confirm that the fryer under test is operating in accordance with its nameplate rating.5.2 Fryer temperature calibration is used to ensure that the fryer being tested is operating at the specified temperature. Temperature calibration also can be used to evaluate and calibrate the thermostat control dial.5.3 Preheat-energy consumption and time can be used by food service operators to manage their restaurants' energy demands, and to estimate the amount of time required for preheating a fryer.5.4 Idle energy and pilot energy rates can be used by food service operators to manage their energy demands.5.5 Preheat energy consumption, idle energy, and pilot energy can be used to estimate the energy consumption of an actual food service operation.5.6 Cooking-energy efficiency is a direct measurement of fryer efficiency at different loading scenarios. This data can be used by food service operators in the selection of fryers, as well as for the management of a restaurant's energy demands.5.7 Production capacity can be used as a measure of fryer capacity by food service operators to choose a fryer to match their particular food output requirements.1.1 This test method covers the evaluation of the energy consumption and cooking performance of open vat fryers. The food service operator can use this evaluation to select a fryer and understand its energy efficiency and production capacity.1.2 This test method is applicable to Types 1 (counter), 2 (drop-in), 3 (floor-mounted, portable), and 4 (floor-mounted, stationary), size A, B, and C, electric (Style A, B and C) and gas (Style D) open vat fryers as defined by Specification F1963, with nominal frying medium capacity up to 50 lb (23 kg) or a vat size less than 18 in. in width. For size C, D, E and F and large open vat fryers with a nominal frying medium capacity greater than 50 lb (23 kg), or a vat size of 18 in. in width or greater, refer to Test Method F2144.1.3 The fryer can be evaluated with respect to the following (where applicable):1.3.1 Energy input rate (10.2),1.3.2 Preheat energy and time (10.4),1.3.3 Idle energy rate (10.5),1.3.4 Pilot energy rate (10.6),1.3.5 Cooking energy rate and efficiency (10.8), and1.3.6 Production capacity and frying medium temperature recovery time (10.8).1.4 This test method is not intended to answer all performance criteria in the evaluation and selection of a fryer, such as the significance of a high energy input design on maintenance of temperature within the cooking zone of the fryer.1.5 The values stated in inch-pound units are to be regarded as the standard. The values given in parentheses are for information only.1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
标准号:
ASTM F1361-21
标准名称:
Standard Test Method for Performance of Open Vat Fryers
英文名称:
Standard Test Method for Performance of Open Vat Fryers标准状态:
Active-
发布日期:
-
实施日期:
出版语种:
- 推荐标准
- AS/NZS 3200.2.21:1994 Approval and test specification - Medical electrical equipment Particular requirements for safety - Infant radiant warmers
- AS/NZS 3200.2.21:1994/Amdt 1:1998 Approval and test specification - Medical electrical equipment - Particular requirements for safety - Infant radiant warmers
- AS/NZS 3350.2.21:1999/Amdt 1:2001 Safety of household and similar electrical appliances - Particular requirements - Storage water heaters
- AS/NZS 3350.2.21:1999/Amdt 3:2004 Safety of household and similar electrical appliances Particular requirements - Storage Water Heaters
- AS/NZS 3350.2.21:1999/Amdt 5:2007 Safety of household and similar electrical appliances Particular requirements - Storage water heaters (IEC 60335-2-21:1997, MOD)
- AS/NZS 3750.21:2008 Paints for steel structures Undercoat - Solvent-borne
- AS/NZS 60335.2.21:2002/Amdt 2:2005 Household and similar electrical appliances - Safety - Particular requirements for storage water heaters
- ASTM 51026-23 Standard Practice for Using the Fricke Dosimetry System
- ASTM 52303-24 Standard Guide for Absorbed-Dose Mapping in Radiation Processing Facilities
- ASTM A1-00(2018) Standard Specification for Carbon Steel Tee Rails
- ASTM A1000/A1000M-17(2023) Standard Specification for Steel Wire, Carbon and Alloy Specialty Spring Quality
- ASTM A1001-18 Standard Specification for High-Strength Steel Castings in Heavy Sections
- ASTM A1002-16(2020) Standard Specification for Castings, Nickel-Aluminum Ordered Alloy
- ASTM A1004/A1004M-99(2018) Standard Practice for Establishing Conformance to the Minimum Expected Corrosion Characteristics of Metallic, Painted-Metallic, and Nonmetallic-Coated Steel Sheet Intended for Use as Cold Formed Framing Members
- ASTM A1009-18 Standard Specification for Soft Magnetic MnZn Ferrite Core Materials for Transformer and Inductor Applications