【国外标准】 Standard Test Method to Determine Efficacy of Disinfection Processes for Reusable Medical Devices (Simulated Use Test) (Withdrawn 2023)
本网站 发布时间:
2024-02-28
- ASTM E1837-96(2014)
- Withdrawn, No replacement
- 定价: 0元 / 折扣价: 0 元
- 在线阅读
开通会员免费在线看70000余条国内标准,赠送文本下载次数,单本最低仅合13.3元!还可享标准出版进度查询、定制跟踪推送、标准查新等超多特权!  
查看详情>>

适用范围:
5.1 This test method is designed to demonstrate and document that reusable devices and medical instruments can be disinfected using a specified technique.5.2 This test method can be used to verify claims of disinfection of recesses, hinged sites, lumina, or other difficult-to-reprocess areas of reusable medical devices and instruments.5.3 This test method also can be used to document the contribution of each element of the reprocessing cycle for reusable medical devices and instruments.5.4 The number of surviving bacteria may be assessed using swabbing and irrigation or total immersion.5.5 This test method may be used to produce quantitative or qualitative results.1.1 This test method is intended to describe a procedure for testing the effectiveness of a disinfection process for reprocessing reusable medical devices when it is tested with a challenge of vegetative cells including mycobacteria. Disinfection normally deals with testing activity against vegetative cells of bacteria, viruses, and fungi. Since this test method is process oriented, the user may wish to examine a variety of test organisms.1.2 This test method is designed to provide a reproducible procedure to verify the effectiveness of a previously validated disinfectant or disinfection procedure for reusable medical instruments and devices.1.3 This test method is not meant to define the effectiveness of or validation of the particular disinfection process used or its kinetics, but rather, it is devised to confirm the effectiveness of the disinfection process by simulating use situations with a particular test process using medical devices and instruments. Either manual or machine reprocessing can be tested.1.4 This test method is intended for use with reusable cleaned and previously sterilized or disinfected (high level) medical instruments and devices. Endoscopes are described in this test method as a worst-case example for contamination and sampling. The selected sterilization or disinfection processes, or both, should have been validated previously, as well as the effectiveness of rinsing for residual sterilant/disinfectant removal determined.1.5 An inoculum with high numbers of selected microorganisms is applied to both test and control, cleaned and sterilized, or disinfected medical instruments. Strains of microorganisms with a recorded resistance to disinfectants are used to contaminate the instrument sites known or suspected to be the most difficult to reprocess.1.6 It is impractical to test for recovery of survivors by immersion of some instruments, for example, endoscopes or some laproscopic instruments, in growth medium because of complexity, size, difficulty in long-term incubation, or deterious effects resulting from incubation. Elution of organisms from the inoculated surfaces, therefore, may be performed to estimate the number of recoverable organisms. Immersion can be used for smaller instruments.1.7 Control instruments are inoculated in the same manner as the test instruments and elution or immersion methods are performed to determine the number of organisms recoverable from the instrument. For channeled devices, such as endoscopes testing, the number of organisms recoverable from the instrument (inside and outside) will serve as the initial control count. It is expected that some fraction of the number of organisms inoculated will be lost in the process of inoculation/drying.1.8 A testing procedure can be performed on a complete reprocessing cycle or can be limited to just the cleaning or disinfection portions of the cycle whether reprocessing is done in a machine or manually.1.9 After the test cycle has been completed, remaining inoculated bacteria will be recovered from test instruments using the same elution procedures as for the control instruments.1.10 Efficacy of a disinfection cycle or reprocessing cycle, or any part thereof, may be determined by comparison of the number of microorganisms recovered from the control instrument (initial recoverable control count) to the recovery determined for the test instruments.1.11 A knowledge of microbiological techniques is required to conduct these procedures.31.12 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
标准号:
ASTM E1837-96(2014)
标准名称:
Standard Test Method to Determine Efficacy of Disinfection Processes for Reusable Medical Devices (Simulated Use Test) (Withdrawn 2023)
英文名称:
Standard Test Method to Determine Efficacy of Disinfection Processes for Reusable Medical Devices (Simulated Use Test) (Withdrawn 2023)标准状态:
Withdrawn, No replacement-
发布日期:
-
实施日期:
出版语种:
- 推荐标准
- AS/NZS 1595:1998 (R2016)/Amdt 1:2014 Cold-rolled, unalloyed, steel sheet and strip
- AS/NZS 1927:2010/Amdt 1:2014 Pedal bicycles - Safety requirements
- AS/NZS 2161.6:2014 Occupational protective gloves Protective gloves for structural firefighting - Laboratory test methods and performance requirements
- AS/NZS 2891.11:2014 Methods of sampling and testing asphalt Degree of particle coating
- AS/NZS 3580.16:2014 Methods for sampling and analysis of ambient air Determination of polycyclic aromatic hydrocarbons (PAH)
- AS/NZS 4474.2:2009/Amdt 2:2014 Performance of household electrical appliances - Refrigerating appliances Energy labelling and minimum energy performance standard requirements
- AS/NZS 4755.3.3:2014 Demand response capabilities and supporting technologies for electrical products Interaction of demand response enabling devices and electrical products - Operational instructions and connections for electric storage and electric-boosted storage water heaters
- AS/NZS 5815.2:2013/Amdt 1:2014 Information technology equipment - Energy performance of computer monitors Minimum energy performance standards (MEPS) and energy rating labels
- AS/NZS 60079.31:2014 Explosive atmospheres Equipment dust ignition protection by enclosure
- AS/NZS 60335.2.96:2002 (R2016)/Amdt 1:2004 Household and similar electrical appliances - Safety - Particular requirements for flexible sheet heating elements for room heating
- AS/NZS ISO 11334.1:2014 Assistive products for walking manipulated by one arm - Requirements and test methods Elbow crutches
- AS/NZS ISO 16840.4:2014 Wheelchair seating Seating systems for use in motor vehicles
- AS/NZS ISO 27729:2014 Information and documentation - International standard name identifier (ISNI)
- ASTM 51026-23 Standard Practice for Using the Fricke Dosimetry System
- ASTM 52303-24 Standard Guide for Absorbed-Dose Mapping in Radiation Processing Facilities