
【国外标准】 Standard Specification for Asbestos-Cement Corrugated Fill For Use in Cooling Towers (Withdrawn 2019)
本网站 发布时间:
2024-02-28
- ASTM C1081-98(2014)
- Withdrawn, No replacement
- 定价: 0元 / 折扣价: 0 元
- 在线阅读
开通会员免费在线看70000余条国内标准,赠送文本下载次数,单本最低仅合13.3元!还可享标准出版进度查询、定制跟踪推送、标准查新等超多特权!  
查看详情>>

适用范围:
This specification covers splash bar and corrugated sheet type asbestos-cement products used as cooling tower fill. This specification does not apply to the following: drift eliminators or demisters, louvers, partitioning and casing panels; asbestos-cement pipes; and asbestos-cement flat sheet fill (heat exchange surfaces). Splash bars are classified into the following types: Type I, splash bars consisting of corrugated autoclaved pressed asbestos-cement sheets for the most demanding applications; Type II, splash bars consisting of corrugated pressed asbestos-cement sheets for intermediate service; and Type III, splash bars intended for less demanding service. The corrugated fill used shall be of Type A, which are non-autoclaved, compressed, corrugated sheet with a specified nominal thickness. Materials shall conform to specified manufacturing (autoclave, pressing, and nominal thickness), composition (cement:silica ratio, mineral diluents, cellulose, maximum organic content, and cement type), and performance (apparent density, water absorption, bending moment, freeze-thaw resistance, Harkort test, and free lime) requirements.1.1 This specification covers splash bar and corrugated sheet type asbestos-cement products used as cooling tower fill.1.2 Drift eliminators or demisters, louvers, partitioning and casing panels are covered in Specifications C1080. Asbestos-cement pipes are covered in Specification C296 and Specifications C428. Asbestos-cement flat sheet fill (heat exchange surfaces) are specified in Specification C1082.1.3 The values stated in the SI system are to be regarded as the standard. The inch-pound units in parentheses are for information only.1.4 Warning—Breathing of asbestos dust is hazardous. Asbestos and asbestos products present demonstrated health risks for users and for those with whom they come into contact. In addition to other precautions, when working with asbestos-cement products, minimize the dust that results. For information on the safe use of chrysoltile asbestos, refer to “Safe Use of Chrysotile Asbestos: A Manual on Preventive and Control Measures.”21.5 The following precautionary caveat pertains only to the Test Method portion, Section 8, of this Specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. See 1.4 for a specific safety hazard.
标准号:
ASTM C1081-98(2014)
标准名称:
Standard Specification for Asbestos-Cement Corrugated Fill For Use in Cooling Towers (Withdrawn 2019)
英文名称:
Standard Specification for Asbestos-Cement Corrugated Fill For Use in Cooling Towers (Withdrawn 2019)标准状态:
Withdrawn, No replacement-
发布日期:
-
实施日期:
出版语种:
- 推荐标准
- ANSI X9.100-181-2014 (R2021) TIFF Image Format for Image Exchange
- ANSI/INCITS/ISO/IEC TR 11581-41:2014[2015] Information technology - User interface icons - Part 41: Data structure to be used by the ISO/IEC JTC 1/SC 35 icon database
- AS 1012.4.2:2014 Methods of testing concrete Determination of air content of freshly mixed concrete - Measuring reduction in air pressure in chamber above concrete
- AS 1180 (Pt 9A to 9C)-1973 Methods of test for hose made from elastomeric materials - Third Group Methods 9A, 9B, 9C
- AS 1678.3C1-1987 Emergency procedure guide - Transport Group text EPGs for Class 3 substances - Flammable liquids - Flammable liquid of lesser hazard
- AS 1684.3 C1 Supp 1-2006 Residential timber-framed construction Cyclonic areas - C1 Supplement 1: Timber framing span tables - Wind classification C1 - Seasoned softwood - Stress Grade F5 (Supplement to AS 1684.3-2006)
- AS 1684.3 C1 Supp 10-1999 Residential timber-framed construction Cyclonic areas - C1 Supplement 10: Timber framing span tables - Wind classification C1 - Unseasoned softwood - Stress Grade F5 (Supplement to AS 1684.3-1999)
- AS 1684.3 C1 Supp 11-1999 Residential timber-framed construction Cyclonic areas - C1 Supplement 11: Timber framing span tables - Wind classification C1 - Unseasoned softwood - Stress Grade F7 (Supplement to AS 1684.3-1999)
- AS 1684.3 C1 Supp 12-2010 Residential timber-framed construction Cyclonic areas - C1 Supplement 12: Timber framing span tables - Wind classification C1 - Unseasoned hardwood - Stress Grade F8 (Supplement to AS 1684.3-2010)
- AS 1684.3 C1 Supp 13-2006 Residential timber-framed construction Cyclonic areas - C1 Supplement 13: Timber framing span tables - Wind classification C1 - Unseasoned hardwood - Stress Grade F11 (Supplement to AS 1684.3-2006)
- AS 1684.3 C1 Supp 14-2006 Residential timber-framed construction Cyclonic areas - C1 Supplement 14: Timber framing span tables - Wind classification C1 - Unseasoned hardwood - Stress Grade F14 (Supplement to AS 1684.3-2006)
- AS 1684.3 C1 Supp 15-1999 Residential timber-framed construction Cyclonic areas - C1 Supplement 15: Timber framing span tables - Wind classification C1 - Unseasoned hardwood - Stress Grade F17 (Supplement to AS 1684.3-1999)
- AS 1684.3 C1 Supp 15-2006 Residential timber-framed construction Cyclonic areas - C1 Supplement 15: Timber framing span tables - Wind classification C1 - Unseasoned hardwood - Stress Grade F17 (Supplement to AS 1684.3-2006)
- AS 1684.3 C1 Supp 2-1999 Residential timber-framed construction Cyclonic areas - C1 Supplement 2: Timber framing span tables - Wind classification C1 - Seasoned softwood - Stress Grade F7 (Supplement to AS 1684.3-1999)
- AS 1684.3 C1 Supp 2-2010 Residential timber-framed construction Cyclonic areas - C1 Supplement 2: Timber framing span tables - Wind classification C1 - Seasoned softwood - Stress Grade F7 (Supplement to AS 1684.3 - 2010)