
【国外标准】 Standard Practice for Use of a Ceric-Cerous Sulfate Dosimetry System
本网站 发布时间:
2024-02-28
开通会员免费在线看70000余条国内标准,赠送文本下载次数,单本最低仅合13.3元!还可享标准出版进度查询、定制跟踪推送、标准查新等超多特权!  
查看详情>>

适用范围:
4.1 The ceric-cerous system provides a reliable means for determining absorbed dose to water. It is based on a process of reduction of ceric ions to cerous ions in acidic aqueous solution by ionizing radiation (1, 4, ICRU Report 80).NOTE 3: The ceric-cerous system described in the practice has cerous sulfate added to the initial solution to reduce the effect of organic impurities and to allow the potentiometric method of measurement. Other systems used for dosimetry include solutions of ceric sulfate or ceric ammonium sulfate in sulfuric acid without the initial addition of cerous sulfate. These other systems are based on the same process of reduction of ceric ions to cerous ions but are not included in this practice.1.1 This practice covers the preparation, testing, and procedure for using the ceric-cerous sulfate dosimetry system to measure absorbed dose to water when exposed to ionizing radiation. The system consists of a dosimeter and appropriate analytical instrumentation. For simplicity, the system will be referred to as the ceric-cerous system. The ceric-cerous dosimeter is classified as a type 1 dosimeter on the basis of the effect of influence quantities. The ceric-cerous system may be used as a reference standard dosimetry system or as a routine dosimetry system.1.2 This document is one of a set of standards that provides recommendations for properly implementing dosimetry in radiation processing, and describes a means of achieving compliance with the requirements of ISO/ASTM Practice 52628 for the ceric-cerous system. It is intended to be read in conjunction with ISO/ASTM Practice 52628.1.3 This practice describes both the spectrophotometric and the potentiometric readout procedures for the ceric-cerous system.1.4 This practice applies only to gamma radiation, X-radiation/bremsstrahlung, and high energy electrons.1.5 This practice applies provided the following conditions are satisfied:1.5.1 The absorbed-dose range is from 5 × 102 to 5 × 104 Gy (1).21.5.2 The absorbed-dose rate does not exceed 106 Gy s−1 (1).1.5.3 For radionuclide gamma-ray sources, the initial photon energy is greater than 0.6 MeV. For bremsstrahlung photons, the initial energy of the electrons used to produce the bremsstrahlung photons is equal to or greater than 2 MeV. For electron beams, the initial electron energy is greater than 8 MeV.NOTE 1: The lower energy limits are appropriate for a cylindrical dosimeter ampoule of 12-mm diameter. Corrections for dose gradient across the ampoule may be required for electron beams (2). The ceric-cerous system may be used at lower energies by employing thinner (in the beam direction) dosimeters (see ICRU Report 35).1.5.4 The irradiation temperature of the dosimeter is above 0°C and below 62°C (3).NOTE 2: The temperature coefficient of dosimeter response is known only in this range (see 5.2). Use outside this range requires determination of the temperature coefficient.1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
标准号:
ASTM ISO/ASTM51205-17
标准名称:
Standard Practice for Use of a Ceric-Cerous Sulfate Dosimetry System
英文名称:
Standard Practice for Use of a Ceric-Cerous Sulfate Dosimetry System标准状态:
Active-
发布日期:
-
实施日期:
出版语种:
- 推荐标准
- AS 5013.17-2004 Food microbiology Milk and milk products - General guidance for the preparation of test samples, initial suspensions and decimal dilutions for microbiological examination
- AS ISO 10006-2003 Quality management systems - Guidelines for quality management in projects
- AS ISO 10014-2007 Quality management systems - Guidelines for realizing financial and economic benefits
- AS ISO 10993.10-2002 Biological evaluation of medical devices Tests for irritation and sensitization
- AS ISO 10993.12-2002 Biological evaluation of medical devices Sample preparation and reference materials
- AS ISO 11137-2002 Sterilization of health care products - Requirements for validation and routine control - Radiation sterilization
- AS ISO 12647.1:2012 Graphic technology - Process control for the production of half-tone colour separations, proof and production prints Parameters and measurement methods
- AS ISO 12647.2-2008 Graphic technology - Process control for the production of half-tone colour separations, proof and production prints Offset lithographic processes
- AS ISO 12647.7:2012 Graphic technology - Process control for the production of half-tone colour separations, proof and production prints Proofing processes working directly from digital data
- AS ISO 12647.8-2012 Graphic technology - Process control for the production of half-tone colour separations, proof and production prints Validation print processes working directly from digital data
- AS ISO 13485-2003 Medical devices - Quality management systems - Requirements for regulatory purposes
- AS ISO 13488-2002 Quality systems - Medical devices - Particular requirements for the application of ISO 9002
- AS ISO 13916-2003 Welding - Guide on the measurement of preheating temperature, interpass temperature and preheat maintenance temperature
- AS ISO 140.8-2006 Acoustics - Measurement of sound insulation in buildings and of building elements Laboratory measurements of the reduction of transmitted impact noise by floor coverings on a heavyweight standard floor
- AS ISO 14021(Int)-1998 Environmental labels and declarations - Self-declared environmental claims