【国外标准】 Standard Test Method for Flammability of a Membrane Switch in Defined Assembly (Withdrawn 2023)
本网站 发布时间:
2024-02-28
- ASTM F2866-11(2019)
- Withdrawn, No replacement
- 定价: 0元 / 折扣价: 0 元
- 在线阅读
开通会员免费在线看70000余条国内标准,赠送文本下载次数,单本最低仅合13.3元!还可享标准出版进度查询、定制跟踪推送、标准查新等超多特权!  
查看详情>>

适用范围:
4.1 There are numerous flammability ratings and tests. Almost without fail, these standards and tests are focused on very specific industries or results, many of which are not applicable to the membrane switch/human machine interface assembly. This test is designed to provide relative results between membrane switches that have been assembled to the unit's final enclosure, housing, etc.4.2 In addition to the test's measurement of the rate of burn, a laboratory can also observe the effects of burning material falling from the test specimen onto other materials (typically a gauze test area) not directly part of the test specimen. The indirect burning is an issue of interest to see if the test specimen will be able to act as an initiator for a far greater and more damaging flame event (fire). Observations should be noted, as qualitative descriptions, as appropriate.4.3 This test can measure the flammability via the use of high-speed photographic or video equipment.4.4 Temperature of the ignition source can be measured via a calibrated thermocouple pyrometer, calorimeter or IR thermometer with an appropriate range.4.5 This test is not designed to provide a PASS or NO PASS status for a switch, rather, it is designed to provide a “grade” for the level of flammability of a membrane switch assembly (as defined in 3.1.10). The end user should make the final determination if the level of flammability is acceptable for the particular application.1.1 This test method covers the determination of the flammability characteristics of a membrane switch.1.2 This test method defines the MSB rating of a membrane switch. Each character of the MSB rating represents a discrete characteristic of a membrane switch performance under destructive thermal loading.1.3 This test procedure will be destructive, but should provide an insight into the relative performance flame-resistance characteristics of differing designs or assemblies, or both.1.4 This test method will focus on the use of convective contact (burner flame) method for ignition, though other methods of ignition are available.1.5 This test method is designed to determine if the membrane switch assembly will add (or detract) from the flame propagation from an exterior flame/fire source.1.6 If this test is intended to be used for an internal flammability source then set up the unit under test (UUT) appropriately and note it in the test scope and results.1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.8 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
标准号:
ASTM F2866-11(2019)
标准名称:
Standard Test Method for Flammability of a Membrane Switch in Defined Assembly (Withdrawn 2023)
英文名称:
Standard Test Method for Flammability of a Membrane Switch in Defined Assembly (Withdrawn 2023)标准状态:
Withdrawn, No replacement-
发布日期:
-
实施日期:
出版语种:
- 推荐标准
- ANSI INCITS TR-11-1992 Information Processing Systems Technical Report - Information Resource Dictionary System (IRDS) Support for Naming Convention Verification (NCV) (NOT AN AMERICAN NATIONAL STANDARD) (formerly ANSI X3/TR-11-1992)
- ANSI X9.105 Part 3-2009 (R2019) Identical to ISO 8583-3:2008 Financial transaction card originated messages - Interchange message specifications - Part 3: Maintenance procedures for messages, data elements and code values
- ANSI X9.105-1:2009 (R2019) (Identical to ISO 8583-1:2009) Financial transaction card originated messages - Interchange message specifications -Part 1: Messages, data elements and code values
- ANSI X9.8-1-2019/ISO 9564-1-2017 Financial services - Personal Identification Number (PIN) management and security - Part 1: Basic principles and requirements for PINs in card-based systems (Identical Adoption)
- ANSI/OPEI B175.2-2012 (R2019) Outdoor Power Equipment - Internal Combustion Engine-Powered Handheld and Backpack Blowers and Blower-Vacuums - Safety Requirements and Performance Testing Procedures
- ANSI/OPEI B175.7-2019 Outdoor Power Equipment - Internal Combustion Engine-Powered Hand-Held Pole Mounted Pruners - Safety and Environmental Requirements
- AS 1085.11-1992/Amdt 1-1993 Railway permanent way material - Head-hardened rails
- AS 1141.11-1996 Methods for sampling and testing aggregates Particle size distribution by sieving
- AS 1301.P11s-1978 Methods of test for pulp and paper (metric units) Klason lignin in wood and pulp
- AS 1333-1994 (R2019)/Amdt 1-2000 Conveyor belting of elastomeric and steel cord construction
- AS 1418.11-2007 Cranes, hoists and winches Vehicle-loading cranes
- AS 1603.11-2010 Automatic fire detection and alarm systems Visual warning devices
- AS 1683.11-1990/Amdt 1-1993 Methods of test for elastomers - Tension testing of vulcanized rubber
- AS 1684 Supp 11-1992 National Timber Framing Code - Timber framing span tables - Seasoned softwood - Stress Grade F8 (Supplement to AS 1684-1992)
- AS 1684 Supp 11-1992/Amdt 1-1994 National Timber Framing Code - Timber framing span tables - Seasoned softwood - Stress Grade F8 (Supplement to AS 1684-1992)