
【国外标准】 Standard Guide for Identification of Bacteriophage Lambda (λ) or Its DNA (Withdrawn 2014)
本网站 发布时间:
2024-02-28
- ASTM E1285-06
- Withdrawn, No replacement
- 定价: 0元 / 折扣价: 0 元
- 在线阅读
开通会员免费在线看70000余条国内标准,赠送文本下载次数,单本最低仅合13.3元!还可享标准出版进度查询、定制跟踪推送、标准查新等超多特权!  
查看详情>>

适用范围:
This guide covers laboratory characterization procedures for identifying bacteriophage lambda or its DNA and assumes that the reader has basic knowledge in virology and molecular biology. Bacteriohage lambda is a temperate bacteriophage with an icosahedral hear and a single, non-contractile tail ending in a single tail fiber. The lambda genome consists of a single molecule of linear double-stranded DNA and has cohesive ends. The naturally preferred hosts is Escherichia coli K12. Hundreds of lambda variants derived from wild type lambda can be used in biotechnology and differ in genome size and genotype. These are used primarily as DNA vectors for cloning DNA fragments. Judging uncontaminated, pure lambda should be done through restriction enzyme analysis DNA characterization and the presence and identification of lambda DNA is accomplished by polymerase chain reaction. The primers used for detection of bacteriophage lambda should be chosen based on the reason for detection.1.1 This guide covers the procedures for identifying bacteriophage lambda used in biotechnology.1.2 There are hundreds of lambda variants that can be used for biotechnology. These lambda variants are derived from wild type lambda and differ in genome size and genotype.1.3 If the bacteriophage lambda is to be used to construct a recombinant molecule, then the same criteria as prescribed in Section 5 should be used to characterize the newly made DNA.
标准号:
ASTM E1285-06
标准名称:
Standard Guide for Identification of Bacteriophage Lambda (λ) or Its DNA (Withdrawn 2014)
英文名称:
Standard Guide for Identification of Bacteriophage Lambda (λ) or Its DNA (Withdrawn 2014)标准状态:
Withdrawn, No replacement-
发布日期:
-
实施日期:
出版语种:
- 推荐标准
- ASTM F3258-23 Standard Specification for Protectors for Rubber Insulating Gloves Meeting Specific Performance Requirements
- ASTM F3259-17 Standard Guide for Micro-computed Tomography of Tissue Engineered Scaffolds
- ASTM F3260-18 Standard Test Method for Determining the Flexural Stiffness of Medical Textiles
- ASTM F3262-17 Standard Classification System for Small Unmanned Aircraft Systems (sUASs) for Land Search and Rescue
- ASTM F3265-17(2023) Standard Test Method for Grid-Video Obstacle Measurement
- ASTM F3268-18a Standard Guide for in vitro Degradation Testing of Absorbable Metals
- ASTM F3270/F3270M-17 Standard Practice for Compression versus Load Properties of Gasket Materials
- ASTM F3273-17(2021)e1 Standard Specification for Wrought Molybdenum-47.5 Rhenium Alloy for Surgical Implants (UNS R03700)
- ASTM F3275-22 Standard Guide for Using a Force Tester to Evaluate Performance of a Brush Part Designed to Clean the Internal Channel of a Medical Device
- ASTM F3276-22 Standard Guide for Using a Force Tester to Evaluate the Performance of a Brush Part Designed to Clean the External Surface of a Medical Device
- ASTM F3277-19 Standard Specification for Cantilevered Steel Bunks Used in Detention and Correctional Facilities
- ASTM F3283/F3283M-18 Standard Specification for the Manufacturing of High-Voltage Proximity Alarm to be used for the Detection of Overhead High Voltage Alternating Current (AC)
- ASTM F3288/F3288M-20 Standard Specification for MRS-Rated Metric- and Inch-sized Crosslinked Polyethylene (PEX) Pressure Pipe
- ASTM F3292-19 Standard Practice for Inspection of Spinal Implants Undergoing Testing
- ASTM F3293-18 Standard Guide for Application of Test Soils for the Validation of Cleaning Methods for Reusable Medical Devices