
【国外标准】 Standard Test Method for Heat Flux Through Evacuated Insulations Using a Guarded Flat Plate Boiloff Calorimeter (Withdrawn 2008)
本网站 发布时间:
2024-02-28
- ASTM C745-92(1999)
- Withdrawn, No replacement
- 定价: 0元 / 折扣价: 0 元
- 在线阅读
开通会员免费在线看70000余条国内标准,赠送文本下载次数,单本最低仅合13.3元!还可享标准出版进度查询、定制跟踪推送、标准查新等超多特权!  
查看详情>>

适用范围:
The thermal performance of multilayer insulations will vary from specimen to specimen due to differences in the material properties, such as the emittance of the reflective shields. In addition, it can vary due to environmental conditioning and the presence of foreign matter such as oxygen or water vapor. Finally, it can vary due to aging, settling, or exposure to excessive mechanical pressures which could wrinkle or otherwise affect the surface texture of the layers. For these reasons, it is imperative that specimen materials be selected carefully to obtain representative samples. It is recommended that several specimens of any one material be tested and no less than four data points obtained for each. For specimens where heat transfer measurements under high-vacuum conditions are required, a preconditioning procedure should be employed to remove water vapor and other outgas components from the multilayer materials.1.1 This test method covers the determination, from cryogenic to near room temperatures, of heat flux through evacuated insulations (Note 1) within the approximate range from 0.3 to 30 W/m . Heat flux values obtained using this method apply strictly only to the particular specimens as tested. Note 1-This test method is primarily intended for use to assess heat flux through evacuated multilayer insulations which are highly anisotropic by nature. Characteristically, multilayer insulations exhibit apparent thermal conductivity values one or two orders of magnitude lower than the best available powder, fiber, or foam insulations. Although this test method is also technically applicable to these latter insulations, other ASTM methods with less stringent requirements are equally applicable and much more economical and practical for such materials. 1.2 This shall be a primary test method for measuring heat flux through evacuated insulations (Note 2), since calibration of the apparatus depends on measurement standards traceable to the National Institute of Standards and Technology (NIST) for length, force, temperature, time, etc. Traceable standards are not yet available for heat flux through standard evacuated reference specimens or transfer standards. Note 2-Values of heat flux for the same materials and environments specified in this method may also be obtained by measuring electrical energy dissipation using a guarded hot plate (Test Method C177) (1, 2) or a guarded cylindrical apparatus (3, 4), or by measuring transient thermal response (5). 1.3 Specimens to be tested using this method shall be flat and may be either a circular or a rectangular configuration, as appropriate for the particular apparatus being used (Note 3). Contoured specimens or those of other shapes must be tested by other methods which are outside the scope of this standard. Specimen sizes and thicknesses shall conform to the limitations specified in Section 7. Note 3-Existing guarded flat plate boil-off calorimeters require circular specimens. For highly anisotropic multilayer insulations, this configuration somewhat simplifies heat transfer calculations, since the resulting heat flow is two-dimensional rather than three-dimensional as it would be for a rectangular specimen. 1.4 Environmental and other parameters that can be varied in the application of this method are ( ) the hot and cold boundary temperatures, ( ) the boundary temperature at the exposed edge of the specimen, ( ) the mechanical compressive pressure to be imposed on the specimen, and ( ) the species and partial pressure of the gas occupying the interlayer cavities of the specimen and the test chamber (Note 4). Hot boundary temperature can be varied within the approximate range from 250 to 670 K, while cold boundary temperature can be varied from approximately 20 to 300 K (Note 5). Selection of boundary temperatures to be imposed at the hot and cold surfaces and at the edge of the specimen shall be subject to the limitations specified in Section 5. Mechanical compressive pressure values to be imposed using this method can vary in the approximate range from 5 to 10 kPa (Note 6). Note 4-Although this test method is primarily intended for use to measure heat flux through evacuated insulations, it is also applicable for measurements where the specimen contains air or other gases at pressures ranging from fully evacuated to atmospheric. However, where measurements are to be made on a specimen that is not evacuated to a pressure of 1 mPa or less, the apparatus shall be provided with a low-conductivity pressure diaphragm to maintain high-vacuum conditions in the annular space between the measuring and guard vessels. Heat transfer through evacuated multilayer insulations can vary significantly from specimen to specimen or from test to test due to the presence of minute but unknown quantities of outgas components (primarily water vapor) within the interstitial cavities. This effect can be minimized with preconditioning of the specimen by extended evacuation at room temperature or by a combination of heat and evacuation over a much shorter time span (see 9.2). Note 5-Cold boundary temperatures down to that of liquid hydrogen (20 K) can be achieved using existing apparatus. Temperatures to approximately 4 K could be achieved with development of an apparatus suitable for use with liquid helium. Note 6-The lower limit of mechanical compressive pressure that can be achieved for any particular specimen is the self-compression value due to the weight of the specimen within the earth's gravitational field. 1.5 Stating that test results were obtained using this specific method requires that all of the variables must be controlled, measured, and recorded as specified herein. 1.6 Details of construction of the calorimeter cannot be covered entirely by this specification since some technical knowledge is required regarding the compatibility of materials with the fluids used, temperature extremes that will be encountered, practical limitations in achieving and controlling the mechanical compressive pressure, and other contingencies. However, existing types of construction and measuring techniques were considered as a guide for this specification and are presented herein as requirements with the realization that developments and improvements can always be made. 1.7 SI units are to be regarded as standard in this test method. Conversion factors for use to obtain imperial equivalents are presented in Table A1.1. 1.8 This standard does not purport to address all of the safety problems, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific precautionary statements are given in Section 6.
标准号:
ASTM C745-92(1999)
标准名称:
Standard Test Method for Heat Flux Through Evacuated Insulations Using a Guarded Flat Plate Boiloff Calorimeter (Withdrawn 2008)
英文名称:
Standard Test Method for Heat Flux Through Evacuated Insulations Using a Guarded Flat Plate Boiloff Calorimeter (Withdrawn 2008)标准状态:
Withdrawn, No replacement-
发布日期:
-
实施日期:
出版语种:
- 推荐标准
- AS/NZS 13818.1 Supp 1:1999 Information technology - Generic coding of moving pictures and associated audio information Systems - Registration procedures (Supplement to AS/NZS 13818.1:1997)
- AS/NZS 13818.1 Supp 2:1999 Information technology - Generic coding of moving pictures and associated audio information Systems - Private data identification (Supplement to AS/NZS 13818.1:1997)
- AS/NZS 13818.2 Supp 1:1999 Information technology - Generic coding of moving pictures and associated audio information Video - Registration of copyright identifiers (Supplement to AS/NZS 13818.2:1997)
- AS/NZS 13818.2 Supp 3:1999 Information technology - Generic coding of moving pictures and associated audio information Video - Multiview profile (Supplement to AS/NZS 13818.2:1997)
- AS/NZS 13818.2 Supp 4:1999 Information technology - Generic coding of moving pictures and associated audio information Video - Extension code assignment (Supplement to AS/NZS 13818.2-1997)
- AS/NZS 1462.19(Int):1999 Methods of test for plastics pipes and fittings C-Ring test for fracture toughness of PVC pipes
- AS/NZS 1477:1999 PVC pipes and fittings for pressure applications
- AS/NZS 1580.101.5:1999 (R2013) Paints and related materials - Methods of test - Conditions of test - Temperature and humidity control
- AS/NZS 1580.208.1:1999 (R2013) Paints and related materials - Methods of test - Thinner compatibility
- AS/NZS 1580.401.1:1999 (R2013) Paints and related materials - Methods of test - Surface dry condition
- AS/NZS 1664.1 Supp 1:1997/Amdt 1:1999 Aluminium structures - Limit state design - Commentary (Supplement to AS/NZS 1664.1:1997)
- AS/NZS 1664.1:1997/Amdt 1:1999 Aluminium structures - Limit state design (Reconfirmed 2020)
- AS/NZS 1664.2 Supp 1:1997/Amdt 1:1999 Aluminium structures - Allowable stress design - Commentary (Supplement to AS/NZS 1664.2:1997) (Reconfirmed 2020)
- AS/NZS 1664.2:1997/Amdt 1:1999 Aluminium structures - Allowable stress design (Reconfirmed 2020)
- AS/NZS 1801:1997/Amdt 1:1999 Occupational protective helmets