【国外标准】 Standard Test Method for Biological Clogging of Geotextile, Drainage Geocomposites, or Soil/Geotextile Filters
本网站 发布时间:
2024-02-28
开通会员免费在线看70000余条国内标准,赠送文本下载次数,单本最低仅合13.3元!还可享标准出版进度查询、定制跟踪推送、标准查新等超多特权!  
查看详情>>

适用范围:
5.1 This test method is performance oriented for determining if, and to what degree, different liquids create biological activity on geotextile filters thereby reducing their flow capability. The use of the method is primarily oriented toward landfill leachates but can be performed with any liquid coming from a particular site or synthesized from a predetermined mixture of biological microorganisms.5.2 The test can be used to compare the flow capability of different types of geotextiles, drainage geocomposite, or soil/geotextile combinations.5.3 This test will usually take considerable time, for example, up to 1000 h, for the biological activity to initiate, grow, and reach an equilibrium condition. The curves resulting from the test are intended to indicate the in-situ behavior of a geotextile or soil/geotextile filter.5.4 The test specimen can be incubated under unsaturated drained conditions between readings, or kept saturated at all times. The first case allows for air penetration into the flow column and thus aerobic conditions. The second case can result in the absence of air; thus it may simulate anaerobic conditions.5.5 The flow rate can be determined using either a constant head test procedure or on the basis of a falling head test procedure. In either case, the flow column containing the geotextile or soil/geotextile is the same; only the head control devices change.NOTE 1: It has been found that once biological clogging initiates, constant head tests often pass inadequate quantities of liquid to accurately measure. It thus becomes necessary to use falling head tests, which can be measured based on time of movement of a relatively small quantity of liquid between two designated points on a clear plastic standpipe.5.6 If the establishment of an unacceptably high degree of clogging is seen in the flow rate curves, the device allows for back flushing with water or with water containing a biocide.5.7 The resulting flow rate curves are intended for use in the design of full-scale geotextile, drainage geocomposite, or soil/geotextile filtration systems and possible remediation schemes in the case of landfill leachate collection and removal systems.1.1 This test method is used to determine the potential for, and relative degree of, biological growth which can accumulate on geotextile, drainage geocomposites, or geotextile/soil filters.1.2 This test method uses the measurement of flow rates over an extended period of time to determine the amount of clogging.1.3 This test method can be adapted for unsaturated as well as saturated conditions.1.4 This test method can use constant head or falling head measurement techniques.1.5 This test method can also be used to give an indication as to the possibility of back flushing, biocide treatment, or both, for remediation purposes if biological clogging does occur.1.6 The values in SI units are to be regarded as the standard. The values provided in inch-pound units are for information only.1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.8 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
标准号:
ASTM D1987-22
标准名称:
Standard Test Method for Biological Clogging of Geotextile, Drainage Geocomposites, or Soil/Geotextile Filters
英文名称:
Standard Test Method for Biological Clogging of Geotextile, Drainage Geocomposites, or Soil/Geotextile Filters标准状态:
Active-
发布日期:
-
实施日期:
出版语种:
- 推荐标准
- AS 1012.10-1985/Amdt 1-1987 Methods of testing concrete - Method for the determination of indirect tensile strength of concrete cylinders ('Brazil' or splitting test)
- AS 1038.22-2000 (R2013) Coal and coke - Analysis and testing Higher rank coal - Mineral matter and water of constitution
- AS 1088.0-1987 Hearing aids Measurement of electroacoustical characteristics
- AS 1088.1-1987 Hearing aids Hearing aids with induction pick-up coil input
- AS 1088.3-1987 Hearing aids Hearing aid equipment not entirely worn on the listener
- AS 1088.4-1987 Hearing aids Magnetic field strength in audio-frequency induction loops for hearing aid purposes
- AS 1088.6-1987 Hearing aids Characteristics of electrical input circuits for hearing aids
- AS 1088.7-1987 Hearing aids Measurement of the performance characteristics of hearing aids for quality inspection for delivery purposes
- AS 1088.8-1987 Hearing aids Method of measurement of performance characteristic of hearing aids under simulated in situ working conditions
- AS 1101.3-1987 Graphical symbols for general engineering Welding and non-destructive examination
- AS 1158.1-1986/Amdt 1-1987 The lighting of urban roads and other public thoroughfares - Performance and installation design requirements
- AS 1158.4-1987 The lighting of urban roads and other public thoroughfares Supplementary lighting at pedestrian crossings
- AS 1311-1987 Steel tendons for prestressed concrete-7-wire stress-relieved steel strand for tendons in prestressed concrete
- AS 1348.4-1987 Road and traffic engineering - Glossary of terms Transport planning
- AS 1410-1987 Sterilizers - Steam - Pre-vacuum