
【国外标准】 Standard Practice for Sampling Zooplankton with Conical Tow Nets
本网站 发布时间:
2024-02-28
开通会员免费在线看70000余条国内标准,赠送文本下载次数,单本最低仅合13.3元!还可享标准出版进度查询、定制跟踪推送、标准查新等超多特权!  
查看详情>>

适用范围:
3.1 The advantages of using conical tow nets are as follows:3.1.1 They are relatively inexpensive and highly versatile in a variety of inland, estuarine, coastal, and marine waters.3.1.2 They can be used from a small or large powered boat with a minimum of auxiliary equipment.3.1.3 They can be used to collect qualitative samples and semiquantitative samples when fitted with a flowmeter and even better samples when fitted with a companion meter on the outside of the hoop to monitor filtering efficiency.3.2 The disadvantages of conical tow nets are as follows:3.2.1 When equipped with a flowmeter they require frequent maintenance including calibration and, in some types, lubrication.3.2.2 They are effective only where drawn through a stream of water having considerable thickness. They are not suitable for collecting samples from a small or restricted region.3.2.3 They are not suitable for collecting in very shallow water.3.2.4 They are clogged by grass beds, coelenterates, and filamentous algae.3.2.5 When used with a flowmeter, they collect only qualitative samples, or semiquantitative samples.3.2.6 When sampling discrete depths using a horizontal tow, the sample can be contaminated from other depths during the deployment and retrieval of the samples if opening and closing devices are not used.3.3 There are several special considerations that shall be observed when using conical tow nets. They are:3.3.1 Conical tow net samplers are designed to be towed at speeds less than three knots; however, greater speeds have been used for the larger nets with a concomitant increase in capture.23.3.2 A conical tow net 0.5 m in diameter or larger shall be used to reduce avoidance by organisms.23.3.3 The nets shall be washed frequently and inspected for pin-size holes, tears, net deterioration, and other anomalies.3.3.4 Nets should be allowed to dry while suspended full length in air and in subdued light prior to storage.3.3.5 Lower catches per sample may result when collections are made during the day. These are particularly noted in the larger zooplanktons.(A) Sage, L. E., “Zooplankton,” In Methods for the Assessment and Prediction of Mineral Mining Impacts on Aquatic Communities: A Review and Analysis, Fish Wildlife Service/Office of Biological Services, Vol 78, No. 30, April 1978, pp. 55–65.1.1 This practice covers the procedure for obtaining qualitative samples of a zooplankton community by use of conical tow nets. Nets will collect most zooplankton, but some forms will avoid nets.1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
标准号:
ASTM E1201-19
标准名称:
Standard Practice for Sampling Zooplankton with Conical Tow Nets
英文名称:
Standard Practice for Sampling Zooplankton with Conical Tow Nets标准状态:
Active-
发布日期:
-
实施日期:
出版语种:
- 推荐标准
- ASTM F3258-23 Standard Specification for Protectors for Rubber Insulating Gloves Meeting Specific Performance Requirements
- ASTM F3259-17 Standard Guide for Micro-computed Tomography of Tissue Engineered Scaffolds
- ASTM F3260-18 Standard Test Method for Determining the Flexural Stiffness of Medical Textiles
- ASTM F3262-17 Standard Classification System for Small Unmanned Aircraft Systems (sUASs) for Land Search and Rescue
- ASTM F3265-17(2023) Standard Test Method for Grid-Video Obstacle Measurement
- ASTM F3268-18a Standard Guide for in vitro Degradation Testing of Absorbable Metals
- ASTM F3270/F3270M-17 Standard Practice for Compression versus Load Properties of Gasket Materials
- ASTM F3273-17(2021)e1 Standard Specification for Wrought Molybdenum-47.5 Rhenium Alloy for Surgical Implants (UNS R03700)
- ASTM F3275-22 Standard Guide for Using a Force Tester to Evaluate Performance of a Brush Part Designed to Clean the Internal Channel of a Medical Device
- ASTM F3276-22 Standard Guide for Using a Force Tester to Evaluate the Performance of a Brush Part Designed to Clean the External Surface of a Medical Device
- ASTM F3277-19 Standard Specification for Cantilevered Steel Bunks Used in Detention and Correctional Facilities
- ASTM F3283/F3283M-18 Standard Specification for the Manufacturing of High-Voltage Proximity Alarm to be used for the Detection of Overhead High Voltage Alternating Current (AC)
- ASTM F3288/F3288M-20 Standard Specification for MRS-Rated Metric- and Inch-sized Crosslinked Polyethylene (PEX) Pressure Pipe
- ASTM F3292-19 Standard Practice for Inspection of Spinal Implants Undergoing Testing
- ASTM F3293-18 Standard Guide for Application of Test Soils for the Validation of Cleaning Methods for Reusable Medical Devices