
【国外标准】 Standard Test Method for Determining Argon Concentration in Sealed Insulating Glass Units Using Spark Emission Spectroscopy
本网站 发布时间:
2024-02-28
开通会员免费在线看70000余条国内标准,赠送文本下载次数,单本最低仅合13.3元!还可享标准出版进度查询、定制跟踪推送、标准查新等超多特权!  
查看详情>>

适用范围:
5.1 This test method is intended to provide a means for determining the concentration of argon in sealed insulating glass units under controlled conditions in compliance with the apparatus manufacturer's instructions.5.2 This is a non-destructive test method in that the edge seal of the test specimen is not breached in order to determine the argon gas concentration. However, damage to some glass coatings on the inner surfaces of the glass can occur.5.3 This test method has been developed based on data collected in a controlled laboratory environment.5.4 The device shall be used to determine the argon gas concentration in insulating glass units in a controlled laboratory environment. Refer to 12.3.5.5 This test method may be used to determine the argon gas concentration before, during, or after the insulating glass unit is subjected to durability tests.5.6 The accuracy of the test method is dependent upon the accuracy of the Spark Emission Spectroscope. When the concentration of the argon being measured is below certain levels, this test method is not applicable. See the spectroscope manufacturer’s literature for recommended levels of accuracy of a given model.1.1 This test method covers procedures for using a spark emission spectroscope to determine the concentration of argon gas in the space between the lites of a sealed insulating glass unit.1.2 This is a non-destructive test method.1.3 This test method shall be used only in a controlled laboratory environment.1.4 This test method is applicable for insulating glass units where argon has been added to the sealed insulating glass cavity and the balance of the gas is atmospheric air.1.5 This test method is applicable for clear, double-glazed insulating glass units.1.6 This test method is applicable for double-glazed insulating glass units with one lite having a metallic coating or tinted glass, or both, and with clear glass as the other lite.1.7 This test method is applicable for triple-glazed insulating glass units only when the center lite of glass has a metallic coating (either low emissivity (low E) or reflective) and both of the other lites are clear glass.1.8 This test method also includes a procedure for verifying the accuracy of the readings of the test apparatus.1.9 The values stated in SI units are to be regarded as standard. The values given in parentheses after SI units are provided for information only and are not considered standard.1.10 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. For specific warning statements, refer to Section 7 on Hazards.1.11 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
标准号:
ASTM E2649-20
标准名称:
Standard Test Method for Determining Argon Concentration in Sealed Insulating Glass Units Using Spark Emission Spectroscopy
英文名称:
Standard Test Method for Determining Argon Concentration in Sealed Insulating Glass Units Using Spark Emission Spectroscopy标准状态:
Active-
发布日期:
-
实施日期:
出版语种:
- 其它标准
- 推荐标准
- ASTM F1591-95(2019) Standard Practice for Visual Signals Between Persons on the Ground and in Aircraft During Ground Emergencies
- ASTM F1592-12(2019) Standard Test Methods for Detention Hollow Metal Vision Systems
- ASTM F1599-95(2018) Standard Guide for Collecting Performance Data on Temporary Storage Devices
- ASTM F1601-01(2023) Standard Test Method for Motor Life Evaluation of an Electric Motorized Nozzle for Central Vacuum Cleaning Systems
- ASTM F1604-15(2020)e1 Standard Specification for Freezers, Ice Cream, Soft Serve, Shake
- ASTM F1606-19 Standard Practice for Rehabilitation of Existing Sewers and Conduits with Deformed Polyethylene (PE) Liner
- ASTM F1607-95(2018) Standard Guide for Reporting of Test Performance Data for Oil Spill Response Pumps
- ASTM F1608-21 Standard Test Method for Microbial Ranking of Porous Packaging Materials (Exposure Chamber Method)
- ASTM F1616-95(2016) Standard Guide for Scope of Performance of First Responders Who Practice in the Wilderness or Delayed or Prolonged Transport Settings
- ASTM F1637-21 Standard Practice for Safe Walking Surfaces
- ASTM F1645/F1645M-22 Standard Test Method for Water Migration in Honeycomb Core Materials
- ASTM F1646-16 Standard Terminology Relating to Walkway Safety and Footwear
- ASTM F1647-11(2018) Standard Test Methods for Organic Matter Content of Athletic Field Rootzone Mixes
- ASTM F1650-21 Standard Practice for Evaluating Tire Traction Performance Data Under Varying Test Conditions
- ASTM F1653-95(2020) Standard Guide for Scope of Performance of Triage in a Prehospital Environment