【国外标准】 Standard Guide for Testing the Resolution of a Raman Spectrometer
本网站 发布时间:
2024-02-28
开通会员免费在线看70000余条国内标准,赠送文本下载次数,单本最低仅合13.3元!还可享标准出版进度查询、定制跟踪推送、标准查新等超多特权!  
查看详情>>

适用范围:
4.1 Assessment of the spectrometer resolution and instrument line shape (ILS) function of a Raman spectrometer is important for intercomparability of spectra obtained among widely varying spectrometer systems, if spectra are to be transferred among systems, if various sampling accessories are to be used, or if the spectrometer can be operated at more than one laser excitation wavelength.4.2 Low-pressure discharge lamps (pen lamps such as mercury, argon, or neon) provide a low-cost means to provide both resolution and wave number calibration for a variety of Raman systems over an extended wavelength range.4.3 There are several disadvantages in the use of emission lines for this purpose, however.4.3.1 First, it may be difficult to align the lamps properly with the sample position leading to distortion of the line, especially if the entrance slit of the spectrometer is underfilled or not symmetrically illuminated.4.3.2 Second, many of the emission sources have highly dense spectra that may complicate both resolution and wave number calibration, especially on low-resolution systems.4.3.3 Third, a significant contributor to line broadening of Raman spectral features may be the excitation laser line width itself, a component that is not assessed when evaluating the spectrometer resolution with pen lamps.4.3.4 An alternative would use a Raman active compound in place of the emission source. This compound should be chemically inert, stable, and safe and ideally should provide Raman bands that are evenly distributed from 0 cm-1 (Raman shift) to the C-H stretching region 3000 cm-1 and above. These Raman bands should be of varying bandwidth.4.4 To date, no such ideal sample has been identified; however carbon tetrachloride (see Practice E1683) and naphthalene (see Guide E1840) have been used previously for both resolution and Raman shift calibration.4.5 The use of calcite to assess the resolution of a Raman system will be addressed in this guide. Calcite is a naturally occurring mineral that possesses many of the desired optical properties for a Raman resolution standard and is inexpensive, safe, and readily available.4.6 The spectral bandwidth of dispersive Raman spectrometers is determined primarily by the focal length of the spectrometer, the dispersion of the grating, and the slit width. Field portable systems typically operate with fixed slits and gratings and thus operate with a fixed spectral bandwidth, while in many laboratory systems the slit widths and gratings are variable. The spectral bandwidth of Fourier-Transform (FT)-Raman systems is continuously variable by altering the optical path difference of the interferometer and furthermore is capable of obtaining much lower spectral bandwidth than most practical dispersive systems. Therefore, data obtained of a narrow Raman band on a FT-Raman system can be used to determine the resolution of a dispersive Raman system. A calibration curve of the full width at half height (FWHH) for the 1085-cm-1 band of calcite as a function of spectral resolution has been reported for this purpose.4 Measurement of this calcite band on a test dispersive instrument enables an estimation of the spectrometer resolution.4.7 This guide will describe the use of calcite and pen lamps for the evaluation of Raman spectrometer resolution for dispersive (grating based) Raman systems operating with a 785 nm laser wavelength.1.1 This guide is designed for routine testing and assessment of the spectral resolution of Raman spectrometers using either a low-pressure arc lamp emission lines or a calibrated Raman band of calcite.1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.1.3 Because of the significant dangers associated with the use of lasers, ANSI Z136.1 shall be followed in conjunction with this practice.1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
标准号:
ASTM E2529-06(2022)
标准名称:
Standard Guide for Testing the Resolution of a Raman Spectrometer
英文名称:
Standard Guide for Testing the Resolution of a Raman Spectrometer标准状态:
Active-
发布日期:
-
实施日期:
出版语种:
- 推荐标准
- ASTM F1252-21 Standard Test Method for Measuring Optical Reflectivity of Transparent Materials
- ASTM F1256-22 Standard Guide for Selection and Practice of Emergency Medical Services Instructor for Emergency Medical Technician (EMT) Training Programs
- ASTM F1264-16e1 Standard Specification and Test Methods for Intramedullary Fixation Devices
- ASTM F1268-90(2020) Standard Guide for Establishing and Operating a Public Information, Education, and Relations Program for Emergency Medical Service Systems
- ASTM F1275-14(2020) Standard Test Method for Performance of Griddles
- ASTM F1276-23 Standard Test Method for Creep Relaxation of Laminated Composite Gasket Materials
- ASTM F1278-96(2021)e1 Standard Guide for Use and Handling of Flexible Retort Food Pouches in the Processing Environment
- ASTM F1279-19 Standard Guide for Ecological Considerations for the Restriction of the Use of Surface Washing Agents: Permeable Land Surfaces
- ASTM F1280-19 Standard Guide for Ecological Considerations for the Use of Surface Washing Agents: Impermeable Surfaces
- ASTM F1284-24 Standard Test Method for Evaluating Carpet Embedded Dirt Removal Effectiveness of Residential Central Vacuum Cleaning Systems
- ASTM F1292-22 Standard Specification for Impact Attenuation of Surfacing Materials Within the Use Zone of Playground Equipment
- ASTM F1301-18(2024)e1 Standard Practice for Labeling Chemical Protective Clothing
- ASTM F1303-04(2021) Standard Specification for Sheet Vinyl Floor Covering with Backing
- ASTM F1306-21 Standard Test Method for Slow Rate Penetration Resistance of Flexible Barrier Films and Laminates
- ASTM F1308-98(2023) Standard Test Method for Quantitating Volatile Extractables in Microwave Susceptors Used for Food Products