
【国外标准】 Standard Specification for Seamless Copper Tube for Medical Gas Systems
本网站 发布时间:
2024-02-28
开通会员免费在线看70000余条国内标准,赠送文本下载次数,单本最低仅合13.3元!还可享标准出版进度查询、定制跟踪推送、标准查新等超多特权!  
查看详情>>

适用范围:
17.1 For purpose of determining compliance with the specified limits for requirements of the properties listed in Table 9, an observed value or calculated value shall be rounded as indicated in accordance with the rounding of Practice E29.AbstractThis specification establishes the requirements for two wall thickness schedules of specially cleaned, straight lengths of seamless copper tube, identified as Types K and L, suitable for medical gas systems. The product shall be manufactured by such hot working necessary to convert the billet to a tubular shape and cold worked to the finished size. Seamless copper tube for medical gas systems shall be furnished in the H58 (Drawn General Purpose) temper. Tension test and Rockwell hardness test shall be performed to determine the tube's tensile strength and hardness, respectively. Eddy-current test, a nondestructive test, shall be performed as well. The tubes used for medical gas systems shall be cleaned by any of the following recommended methods: alkaline washing, steam solvent washing, steam detergent washing, steam washing, vapor degreasing, and refrigerant degreasing.1.1 This specification establishes the requirements for two wall thickness schedules of specially cleaned, straight lengths of seamless copper tube, identified as Types K and L, suitable for medical gas systems. The tube shall be installed in conformance with the requirements of the National Fire Protection Association (NFPA) Standard 99, Gas and Vacuum Systems (NFPA) Standard 99C, Standard for Hypobaric Facilities (NFPA) Standard 99B, and Canadian Standards Association (CSA) Standard Z 305.1/Z 7396.1, Nonflammable Medical Gas Piping Systems.NOTE 1: Types K and L tube are defined in Specification B88.NOTE 2: Drawn temper tube is suitable for use with capillary (solder joint) fittings for brazing.1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.1.3 The following safety hazard caveat pertains only to the test method portion of Section 12 of this specification. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.21.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
标准号:
ASTM B819-19
标准名称:
Standard Specification for Seamless Copper Tube for Medical Gas Systems
英文名称:
Standard Specification for Seamless Copper Tube for Medical Gas Systems标准状态:
Active-
发布日期:
-
实施日期:
出版语种:
- 推荐标准
- ANSI/OPEI B175.2-2012 (R2019) Outdoor Power Equipment - Internal Combustion Engine-Powered Handheld and Backpack Blowers and Blower-Vacuums - Safety Requirements and Performance Testing Procedures
- ANSI/OPEI B175.6-2018 Outdoor Power Equipment - Internal Combustion Engine-Powered Hand-Held Hedge Trimmers - Safety and Environmental Requirements
- ANSI/OPEI B175.7-2019 Outdoor Power Equipment - Internal Combustion Engine-Powered Hand-Held Pole Mounted Pruners - Safety and Environmental Requirements
- AS 1012.19-1988 Methods of testing concrete Accelerated curing of concrete compression test specimens (laboratory or field) - Hot water and warm water methods
- AS 1418.19-2007 Cranes, hoists and winches Telescopic handlers
- AS 2001.7.19-1990 Methods of test for textiles Quantitative analysis of fibre mixtures - Binary mixtures of chlorofibres (homopolymers of vinyl chloride) and certain other fibres (method using concentrated sulfuric acid)
- AS 2359.19-2008 Powered industrial trucks Additional stability tests for industrial variable-reach trucks handling freight containers of length 6 m and above
- AS 2545/B-1987 (Reference Use Only) Subcontract conditions - Annexure to AS 2545 including certificate of substantial completion form of formal instrument of agreement
- AS 2545/B-1993 (Reference Use Only) Subcontract conditions (AS 2545-1993) - Annexure Part B
- AS 4276.19:2014 Water microbiology Examination for thermophilic Campylobacter spp. - Membrane filtration
- AS 5013.19.1-2012 Food microbiology Microbiology of food and animal feeding stuffs - Horizontal method for the enumeration of ß-glucuronidase-positive Escherichia coli-Colony-count technique at 44°C using membranes and 5-bromo-4-chloro-3-indolylß-D-glucuronide (ISO 16649-1:2001, MOD)
- ASTM D4882-17 Standard Test Method for Bond Strength of Electrical Insulating Varnishes by the Twisted-Coil Test
- ASTM D4883-18 Standard Test Method for Density of Polyethylene by the Ultrasound Technique
- ASTM D4886-23 Standard Test Method for Abrasion Resistance of Geotextiles (Sandpaper/Sliding Block Method)
- ASTM D4887/D4887M-11(2021)e1 Standard Practice for Preparation of Viscosity Blends for Hot Recycled Asphalt Materials