【国外标准】 Standard Test Method for Determining Forming Limit Curves
本网站 发布时间:
2024-02-28
开通会员免费在线看70000余条国内标准,赠送文本下载次数,单本最低仅合13.3元!还可享标准出版进度查询、定制跟踪推送、标准查新等超多特权!  
查看详情>>

适用范围:
5.1 The forming limit curve (FLC) is specific to the material sampled. It can change if the material is subjected to cold work or any annealing process. Thus, two samples from a given lot of material can produce different curves if their processing is varied.5.2 The processing history of the material must be known if the test is to be considered representative of a grade of a product.5.3 A forming limit curve (FLC) defines the maximum (limiting) strain that a given sample of a sheet metal can undergo for a range of forming conditions, such as deep drawing, plane strain, biaxial stretching, and bending over a radius in a press and die drawing operation, without developing a localized zone of thinning (localized necking) that would indicate incipient failure.5.3.1 FLCs may be obtained empirically by using a laboratory hemispherical punch biaxial stretch test and also a tension test to strain metal sheet test specimens, from a material sample, from beyond their elastic limit to just prior to localized necking and fracture.5.3.1.1 Since the location of localized necking and fracture cannot be predetermined, one or both surfaces of test specimens are covered with a pattern of gauge length measurement units, usually as squares or small diameter circles, by a suitable method such as scribing, photo-grid, or electro-etching, and then each test specimen is formed to the point of localized necking, or fracture.5.3.2 Strains in the major (e1) and minor (e2) directions are measured using individual gauge length measurement units on the pattern in the area of the localized necking or fracture.5.3.2.1 Test specimens of varied widths are used to produce a wide range of strain states in the minor (e2) direction.5.3.2.2 The major strain (e1) is determined by the capacity of the material to be stretched in one direction as simultaneous surface forces either stretch, do not change, or compress, the metal in the minor strain (e2) direction.5.3.2.3 In the tension test deformation process, the minor strains (e2) are negative, and the test specimen is narrowed both through the thickness and across its width.5.3.3 These strains are plotted on a forming limit diagram (FLD), and the forming limit curve (FLC) is drawn to connect the highest measured e1 and e2 strain combinations that include good data points.5.3.3.1 When there is intermixing and no clear distinction between good and marginal data points, a best fit curve is established to follow the maximum good data points as the FLC.5.3.4 The forming limit is established at the maximum major strain (e1) attained prior to necking.5.3.5 The FLC defines the limit of useful deformation in forming metallic sheet products.5.3.6 FLCs are known to change with material (specifically with the mechanical or formability properties developed during the processing operations used in making the material) and the thickness of the sheet metal.5.3.6.1 The strain hardening exponent (n value), defined in Test Method E646, affects the forming limit. A high n value will raise the limiting major strain (e1), allowing more stretch under positive minor strain conditions (e2 > 0).5.3.6.2 The plastic strain ratio (r value), defined in Test Method E517, affects the capacity of a material to be deep drawn. A high r value will move the minor strain (e2) into a less severe area to the left of the FLDo (e2 < 0), thus permitting deeper draws for a given major strain (e1).5.3.6.3 The thickness of the material will affect the FLC since a thicker test specimen has more volume to respond to the forming process.5.3.6.4 The properties of the steel sheet product used in determining the FLC of Fig. 3 included the n value and the r value.5.3.7 FLCs serve as a diagnostic tool for material strain analysis and have been used for evaluations of stamping operations and material selection.5.3.8 The FLC provides a graphical basis for comparison with strain distributions on parts formed by sequential press operations.5.3.9 The FLC obtained by this method follows a constant proportional strain path where there is a nominally fixed ratio of major (e1) to minor (e2) strain.5.3.9.1 There is no interrupted loading, or reversal of straining, but the rate of straining may be slowed as the test specimen approaches necking or fracture.5.3.9.2 The FLC can be used for conservatively predicting the performance of an entire class of materials provided the n value, r value, and thickness of the material used are representative of that class.5.3.10 Complex forming operations, in which the strain path changes, or the strain is not homogeneous through the metal sheet thickness, can produce limiting strains that do not agree with the forming limit obtained by this method.5.3.11 Characterization of a material's response to plastic deformation can involve strain to fracture as well as to the onset of necking. These strains are above the FLC.5.3.12 The FLC is not suitable for lot-to-lot quality assurance testing because it is specific to that sample of a material which is tested to establish the forming limit.1.1 This test method gives the procedure for constructing a forming limit curve (FLC) for a metallic sheet material by using a hemispherical deformation punch test and a uniaxial tension test to quantitatively simulate biaxial stretching and deep drawing processes.1.1.1 Fig. 1 shows an example of a forming limit curve on a schematic forming limit diagram (FLD).FIG. 1 Schematic Forming Limit DiagramNOTE 1: The upper curve represents the forming limit curve. Strains below the lower curve do not occur during forming metallic sheet products in the most stamping press operations. Curves to the left of % e2 = 0 are for constant area of the test specimen surface.1.2 FLCs are useful in evaluating press performance by metal fabrication strain analysis.1.3 The method applies to metallic sheet from 0.5 mm (0.020 in.) to 3.3 mm (0.130 in.).1.4 The values stated in SI units are to be regarded as the standard. The values given in parentheses after SI units are provided for information only and are not considered standard.1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
标准号:
ASTM E2218-23
标准名称:
Standard Test Method for Determining Forming Limit Curves
英文名称:
Standard Test Method for Determining Forming Limit Curves标准状态:
Active-
发布日期:
-
实施日期:
出版语种:
- 推荐标准
- INCITS/ISO/IEC 2382-23:1994[R2011] Information Proccessing Systems - Vocabulary Part 23: Text Processing (formerly ANSI/ISO/IEC 2382-23-1994)
- INCITS/TR-23-1998 (R2018) Information Techology - SCSI Enhanced Parallel Interface (EPI)
- ASTM D8137-18(2023) Practice for Accelerated Aging of Leather
- ASTM D8138-23 Standard Specification for Preformed Silicone Joint Sealing System for Bridges
- ASTM D8139-23 Standard Specification for Semi-Rigid, Closed-Cell Polypropylene Foam, Preformed Expansion Joint Fillers for Concrete Paving and Structural Construction
- ASTM D814-95(2020) Standard Test Method for Rubber Property—Vapor Transmission of Volatile Liquids
- ASTM D8140-18(2023) Standard Guide for the Use of Foundry Sand in Asphalt Mixtures
- ASTM D8141-22 Standard Guide for Selecting Volatile Organic Compounds (VOCs) and Semi-Volatile Organic Compounds (SVOCs) Emission Testing Methods to Determine Emission Parameters for Modeling of Indoor Environments
- ASTM D8144-22 Standard Test Method for Separation and Determination of Aromatics, Nonaromatics, and FAME Fractions in Middle Distillates by Solid-Phase Extraction and Gas Chromatography
- ASTM D8148-22 Standard Test Method for Spectroscopic Determination of Haze in Fuels
- ASTM D8149-20 Standard Practice for Optimization, Calibration, and Validation of Ion Chromatographic Determination of Heteroatoms and Anions in Petroleum Products and Lubricants
- ASTM D8150-22 Standard Test Method for Determination of Organic Chloride Content in Crude Oil by Distillation Followed by Detection Using Combustion Ion Chromatography
- ASTM D8152-18 Standard Practice for Measuring Field Infiltration Rate and Calculating Field Hydraulic Conductivity Using the Modified Philip Dunne Infiltrometer Test
- ASTM D8154-24 Standard Test Methods for 1H-NMR Determination of Ketone-Ethylene-Ester and Polyvinyl Chloride Contents in KEE-PVC Roofing Fabrics
- ASTM D8155-17(2023) Standard Practice for Shake Extraction of Solid Mining and Metallurgical Processing Waste with Water