
【国外标准】 Standard Test Method for Conducting Cyclic Potentiodynamic Polarization Measurements to Determine the Corrosion Susceptibility of Small Implant Devices
本网站 发布时间:
2024-02-28
开通会员免费在线看70000余条国内标准,赠送文本下载次数,单本最低仅合13.3元!还可享标准出版进度查询、定制跟踪推送、标准查新等超多特权!  
查看详情>>

适用范围:
5.1 Corrosion of implantable medical devices can have deleterious effects on the device performance or may result in the release of corrosion products with harmful biological consequences; therefore it is important to determine the general corrosion behavior as well as the susceptibility of the devices to localized corrosion.5.2 The forming and finishing steps used to create an implantable device may have significant effects on the corrosion resistance of the material out of which the device is fabricated. During the selection process of a material for use as an implantable device, testing the corrosion resistance of the material is an essential step; however, it does not necessarily provide critical data regarding device performance.5.3 To accommodate the wide variety of device shapes and sizes encountered, a variety of holding devices can be used.5.4 Note that the method is intentionally designed to reach conditions that are sufficiently severe to cause breakdown and deterioration of the medical devices and that these conditions may not necessarily be encountered in vivo. The results of this corrosion test conducted in artificial physiological electrolytes can provide useful data for comparison of different device materials, designs, or manufacturing processes. However, note that this test method does not take into account the effects of cells, proteins, and so forth, on the corrosion behavior in vivo.1.1 This test method assesses the corrosion susceptibility of small, metallic, implant medical devices, or components thereof, using cyclic (forward and reverse) potentiodynamic polarization. Examples of device types that may be evaluated by this test method include, but are not limited to, vascular stents, ureteral stents (Specification F1828), filters, support segments of endovascular grafts, cardiac occluders, aneurysm or ligation clips, staples, and so forth.1.2 This test method is used to assess a device in its final form and finish, as it would be implanted. These small devices should be tested in their entirety. The upper limit on device size is dictated by the electrical current delivery capability of the test apparatus (see Section 6). It is assumed that test methods, such as Reference Test Method G5 and Test Method G61 have been used for material screening.1.3 Because of the variety of configurations and sizes of implants, this test method provides a variety of specimen holder configurations.1.4 This test method is intended for use on implantable devices made from metals with a relatively high resistance to corrosion.1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
标准号:
ASTM F2129-19a
标准名称:
Standard Test Method for Conducting Cyclic Potentiodynamic Polarization Measurements to Determine the Corrosion Susceptibility of Small Implant Devices
英文名称:
Standard Test Method for Conducting Cyclic Potentiodynamic Polarization Measurements to Determine the Corrosion Susceptibility of Small Implant Devices标准状态:
Active-
发布日期:
-
实施日期:
出版语种:
- 推荐标准
- ASTM A732/A732M-20 Standard Specification for Castings, Investment, Carbon and Low-Alloy Steel for General Application, and Cobalt Alloy for High Strength at Elevated Temperatures
- ASTM A737/A737M-17 Standard Specification for Pressure Vessel Plates, High-Strength, Low-Alloy Steel
- ASTM A740-21 Standard Specification for Hardware Cloth (Woven or Welded Galvanized Steel Wire Fabric)
- ASTM A743/A743M-21 Standard Specification for Castings, Iron-Chromium, Iron-Chromium-Nickel, Corrosion Resistant, for General Application
- ASTM A745/A745M-20 Standard Practice for Ultrasonic Examination of Austenitic Steel Forgings
- ASTM A746-18(2022) Standard Specification for Ductile Iron Gravity Sewer Pipe
- ASTM A748/A748M-87(2022) Standard Specification for Statically Cast Chilled White Iron-Gray Iron Dual Metal Rolls for Pressure Vessel Use
- ASTM A751-21 Standard Test Methods and Practices for Chemical Analysis of Steel Products
- ASTM A754/A754M-21 Standard Test Method for Coating Weight [Mass] of Metallic Coatings on Steel by X-Ray Fluorescence
- ASTM A756-17(2022) Standard Specification for Stainless Anti-Friction Bearing Steel
- ASTM A757/A757M-22 Standard Specification for Steel Castings, Ferritic and Martensitic, for Pressure-Containing and Other Applications, for Low-Temperature Service
- ASTM A762/A762M-19 Standard Specification for Corrugated Steel Pipe, Polymer Precoated for Sewers and Drains
- ASTM A763-15(2021) Standard Practices for Detecting Susceptibility to Intergranular Attack in Ferritic Stainless Steels
- ASTM A765/A765M-07(2022) Standard Specification for Carbon Steel and Low-Alloy Steel Pressure-Vessel-Component Forgings with Mandatory Toughness Requirements
- ASTM A770/A770M-03(2018) Standard Specification for Through-Thickness Tension Testing of Steel Plates for Special Applications