【国外标准】 Standard Test Methods for Refractive Index and Specific Optical Dispersion of Electrical Insulating Liquids (Withdrawn 2014)
本网站 发布时间:
2024-02-28
- ASTM D1807-00(2005)e1
- Withdrawn, No replacement
- 定价: 0元 / 折扣价: 0 元
- 在线阅读
开通会员免费在线看70000余条国内标准,赠送文本下载次数,单本最低仅合13.3元!还可享标准出版进度查询、定制跟踪推送、标准查新等超多特权!  
查看详情>>

适用范围:
Refractive Index—The refractive index of an insulating liquid varies with its composition and with the nature and amount of contaminants held in solution. Changes of refractive index with time and service may form a basis for estimating any change in composition or the degree of contaminant acquired in service. For electrical insulating mineral oils, the wavelength of 5893 ˚A for the spectral line of sodium is commonly used. The test temperature is 25°C.Specific Optical Dispersion—Specific optical dispersion serves as a quick index to the amount of unsaturated compounds present in an oil. Dispersion values for paraffinic and naphthenic compounds are nearly the same and are essentially independent of molecular weight and structural differences. Values above 97 bear a direct relationship to the amount of aromatic compounds present in insulating oil. For convenience, the specific dispersion value is multiplied by 10 4. For electrical insulating mineral oils, the wavelengths of 6563 and 4861 ˚A corresponding to the spectral lines of hydrogen are commonly used. Alternatively, the wavelengths of 6678 and 5016 ˚A corresponding to the spectral lines of helium may be used.1.1 These test methods cover the determination of the refractive index and the specific optical dispersion of electrical insulating liquids such as are used in capacitors, transformers, circuit breakers, and oil-filled cables.1.2 Two test methods are described, a routine method and a more precise referee method. Both methods are applicable to transparent, light-colored, insulating liquids.1.2.1 The routine method is used to determine refractive index and specific optical dispersion as described in these test methods.1.2.2 The referee method is used when a test of high accuracy is desired. These methods are described in Test Method D1218. Specific optical dispersion is calculated by dividing the refractive dispersion value determined in Test Method D1218 by the relative density (specific gravity) (see Test Method D1298) of the liquid under test.1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
标准号:
ASTM D1807-00(2005)e1
标准名称:
Standard Test Methods for Refractive Index and Specific Optical Dispersion of Electrical Insulating Liquids (Withdrawn 2014)
英文名称:
Standard Test Methods for Refractive Index and Specific Optical Dispersion of Electrical Insulating Liquids (Withdrawn 2014)标准状态:
Withdrawn, No replacement-
发布日期:
-
实施日期:
出版语种:
- 推荐标准
- AS/NZS 1338.1:1992/Amdt 1:1994 Filters for eye protectors - Filters for protection against radiation generated in welding and allied operations
- AS/NZS 13818.1 Supp 1:1999 Information technology - Generic coding of moving pictures and associated audio information Systems - Registration procedures (Supplement to AS/NZS 13818.1:1997)
- AS/NZS 13818.2 Supp 1:1999 Information technology - Generic coding of moving pictures and associated audio information Video - Registration of copyright identifiers (Supplement to AS/NZS 13818.2:1997)
- AS/NZS 1429.1:2000/Amdt 1:2002 Electric cables - Polymeric insulated For working voltages 1.9/3.3 (3.6) kV up to and including 19/33 (36) kV
- AS/NZS 1554.1:1995/Amdt 1:1998 Structural steel welding - Welding of steel structures
- AS/NZS 1554.3:2002/Amdt 1:2003 Structural steel welding Welding of reinforcing steel
- AS/NZS 1595:1998 (R2016)/Amdt 1:2014 Cold-rolled, unalloyed, steel sheet and strip
- AS/NZS 1660.2.1:1998 (R2017)/Amdt 1:2001 Test methods for electric cables, cords and conductors - Insulation, extruded semi-conductive screens and non-metallic sheaths - Methods for general application
- AS/NZS 1660.2.4:1998 (R2017)/Amdt 1:2001 Test methods for electric cables, cords and conductors - Insulation, extruded semi-conductive screens and non-metallic sheaths - Methods specific to polyethylene and polypropylene materials
- AS/NZS 1660.2.5:1998 (R2017)/Amdt 1:2001 Test methods for electric cables, cords and conductors - Insulation, extruded semi-conductive screens and non-metallic sheaths - Methods specific to cables above 1 kV
- AS/NZS 1660.5.6:1998/Amdt 1:2001 Test methods for electric cables, cords and conductors - Fire tests - Test for combustion propagation
- AS/NZS 1664.1 Supp 1:1997/Amdt 1:1999 Aluminium structures - Limit state design - Commentary (Supplement to AS/NZS 1664.1:1997)
- AS/NZS 1664.1:1997/Amdt 1:1999 Aluminium structures - Limit state design (Reconfirmed 2020)
- AS/NZS 1664.2 Supp 1:1997/Amdt 1:1999 Aluminium structures - Allowable stress design - Commentary (Supplement to AS/NZS 1664.2:1997) (Reconfirmed 2020)
- AS/NZS 1664.2:1997/Amdt 1:1999 Aluminium structures - Allowable stress design (Reconfirmed 2020)