【国外标准】 Standard Practice for Evaluating Efficacy of Vaporous Decontaminants on Materials Contaminated with Bacillus Spores and Contained Within 0.2µm Filter-Capped Tubes
本网站 发布时间:
2024-02-28
开通会员免费在线看70000余条国内标准,赠送文本下载次数,单本最低仅合13.3元!还可享标准出版进度查询、定制跟踪推送、标准查新等超多特权!  
查看详情>>

适用范围:
5.1 The practice can be used to evaluate coupon materials of any composition, insofar as the coupon can be prepared small enough to fit inside a 50-ml conical tube.5.2 This practice defines procedures that are quantitative, scalable, rapid, sensitive, safe, reduces consumables, minimizes labor and addresses statistical confidence (1, 2, 4).5.2.1 Quantitative—The total number of spores per coupon is determined by dilution-plating, and all spores remaining on the coupon are assayed for activity in the extraction tube to provide confidence that 100 % of spores were assayed.5.2.2 Statistical Confidence—The use of five independent preparations of spore inoculum for a statistical N of 5.5.2.3 Sensitivity—Allows for complete detection of all viable spores inoculated on a coupon, including the spores that remain attached to the coupon.5.2.4 Safety—Inoculated coupons are contained within 0.2 µm filter-capped 50-ml conical tubes. The 0.2 µm filter allows vaporous decontaminants to pass through while preventing escape of spores, thereby providing an important level of containment when working with pathogenic strains.5.2.5 Simplicity of Testing—Tests and extractions are performed in the same 50-ml conical tube to minimize handling steps.5.2.6 Scalable and Rapid—A maximum of 36 samples can be processed in 1 h by two technicians; a total of 300 samples have been processed by six technicians in 5 h (1-3).5.2.7 Wide application for numerous Bacillus species and strains.NOTE 1: This practice differs from similar quantitative methods (E2111, E2197 and E2414) in the size and variety of coupon materials available for testing, in the practical confidence of the statistics, the application of the decontaminant, scalability and sensitivity.1.1 This practice is used to quantify the efficacy of vaporous decontaminants on Bacillus spores dried on the surface of coupons made from porous and non-porous materials and contained within 0.2µm filter-capped tubes.1.2 This practice should be performed only by those trained in microbiological techniques, are familiar with antimicrobial (sporicidal) agents and with the end use of such products.1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
标准号:
ASTM E3092-18
标准名称:
Standard Practice for Evaluating Efficacy of Vaporous Decontaminants on Materials Contaminated with Bacillus Spores and Contained Within 0.2µm Filter-Capped Tubes
英文名称:
Standard Practice for Evaluating Efficacy of Vaporous Decontaminants on Materials Contaminated with Bacillus Spores and Contained Within 0.2µm Filter-Capped Tubes标准状态:
Active-
发布日期:
-
实施日期:
出版语种:
- 推荐标准
- ASTM E423-71(2019) Standard Test Method for Normal Spectral Emittance at Elevated Temperatures of Nonconducting Specimens
- ASTM E424-71(2023) Standard Test Methods for Solar Energy Transmittance and Reflectance (Terrestrial) of Sheet Materials
- ASTM E431-96(2022) Standard Guide to Interpretation of Radiographs of Semiconductors and Related Devices
- ASTM E433-71(2023) Standard Reference Photographs for Liquid Penetrant Inspection
- ASTM E434-10(2020) Standard Test Method for Calorimetric Determination of Hemispherical Emittance and the Ratio of Solar Absorptance to Hemispherical Emittance Using Solar Simulation
- ASTM E436-03(2021) Standard Test Method for Drop-Weight Tear Tests of Ferritic Steels
- ASTM E438-92(2024) Standard Specification for Glasses in Laboratory Apparatus
- ASTM E439-23 Standard Test Methods for Chemical Analysis of Beryllium
- ASTM E445/E445M-15(2019) Standard Test Method for Stopping Distance on Paved Surfaces Using a Passenger Vehicle Equipped with Full-Scale Tires
- ASTM E446-20 Standard Reference Radiographs for Steel Castings Up to 2 in. (50.8 mm) in Thickness
- ASTM E45-18a(2023) Standard Test Methods for Determining the Inclusion Content of Steel
- ASTM E452-02(2023) Standard Test Method for Calibration of Refractory Metal Thermocouples Using a Radiation Thermometer
- ASTM E454-12(2021) Standard Specification for Industrial Perforated Plate and Screens (Square Opening Series)
- ASTM E455-19 Standard Test Method for Static Load Testing of Framed Floor or Roof Diaphragm Constructions for Buildings
- ASTM E457-08(2020) Standard Test Method for Measuring Heat-Transfer Rate Using a Thermal Capacitance (Slug) Calorimeter