【国外标准】 Standard Practice for Use of Gel Filtration Columns for Cytotoxicity Reduction and Neutralization
本网站 发布时间:
2024-02-28
开通会员免费在线看70000余条国内标准,赠送文本下载次数,单本最低仅合13.3元!还可享标准出版进度查询、定制跟踪推送、标准查新等超多特权!  
查看详情>>

适用范围:
5.1 This practice is to be used for the removal of virucidal agents from test product-virus mixtures, or from test product-neutralizer-virus mixtures, at or after the contact period and before the inoculation of these mixtures into host systems for assay of viral infectivity.5.2 The purpose of the practice is to reduce the concentration of the cytotoxic properties of the test product and neutralizers in order to permit the evaluation of viral infectivity at dilutions that would otherwise be toxic to the host cells.5.3 The practice is applicable to the testing of liquid, pre-saturated towelettes, and pressurized disinfectant products, as well as handwash/rub products.NOTE 3: When testing products, the ability of the solution to pass through the column must be verified prior to testing. Certain products with high viscosities are unable to pass through columns. If the product is determined to be too viscous, alternative neutralization methods should be employed.5.4 This practice is compatible with organic soil loads, hard water, disinfectants containing organic solvents, and chemical neutralizers.1.1 This practice is intended to be used to reduce the cytotoxic level of the virus-test product mixture prior to assaying for viral infectivity. It is used in conjunction with evaluations of the virucidal efficacy of disinfectant solutions, wipes, trigger sprays, or pressurized disinfectant spray products intended for use on inanimate, nonporous environmental surfaces. This practice may also be used in the evaluation of hygienic handwashes/handrubs, or for other special applications. The practice may be employed with all viruses and host systems.NOTE 1: Gel filtration columns may impact virus titer and their use should be taken into consideration when selected for use.1.2 This practice should be performed only by persons trained in virology techniques.1.3 This practice utilizes gel filtration technology. The effectiveness of the practice is dependent on the ratio of gel bed volume to sample size and uniformity in the preparation of columns as well as the conditions of centrifugation. The effectiveness of this practice is maximized by investigator practice and experience with gel filtration techniques.1.4 This practice will aid in the reduction, but not necessarily elimination, of test product toxicity while preserving the titer of the input virus.1.5 Units—The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
标准号:
ASTM E1482-23
标准名称:
Standard Practice for Use of Gel Filtration Columns for Cytotoxicity Reduction and Neutralization
英文名称:
Standard Practice for Use of Gel Filtration Columns for Cytotoxicity Reduction and Neutralization标准状态:
Active-
发布日期:
-
实施日期:
出版语种:
- 推荐标准
- INCITS/ISO/IEC 2382-23:1994[R2011] Information Proccessing Systems - Vocabulary Part 23: Text Processing (formerly ANSI/ISO/IEC 2382-23-1994)
- INCITS/TR-23-1998 (R2018) Information Techology - SCSI Enhanced Parallel Interface (EPI)
- ASTM D8137-18(2023) Practice for Accelerated Aging of Leather
- ASTM D8138-23 Standard Specification for Preformed Silicone Joint Sealing System for Bridges
- ASTM D8139-23 Standard Specification for Semi-Rigid, Closed-Cell Polypropylene Foam, Preformed Expansion Joint Fillers for Concrete Paving and Structural Construction
- ASTM D814-95(2020) Standard Test Method for Rubber Property—Vapor Transmission of Volatile Liquids
- ASTM D8140-18(2023) Standard Guide for the Use of Foundry Sand in Asphalt Mixtures
- ASTM D8141-22 Standard Guide for Selecting Volatile Organic Compounds (VOCs) and Semi-Volatile Organic Compounds (SVOCs) Emission Testing Methods to Determine Emission Parameters for Modeling of Indoor Environments
- ASTM D8144-22 Standard Test Method for Separation and Determination of Aromatics, Nonaromatics, and FAME Fractions in Middle Distillates by Solid-Phase Extraction and Gas Chromatography
- ASTM D8148-22 Standard Test Method for Spectroscopic Determination of Haze in Fuels
- ASTM D8149-20 Standard Practice for Optimization, Calibration, and Validation of Ion Chromatographic Determination of Heteroatoms and Anions in Petroleum Products and Lubricants
- ASTM D8150-22 Standard Test Method for Determination of Organic Chloride Content in Crude Oil by Distillation Followed by Detection Using Combustion Ion Chromatography
- ASTM D8152-18 Standard Practice for Measuring Field Infiltration Rate and Calculating Field Hydraulic Conductivity Using the Modified Philip Dunne Infiltrometer Test