【国外标准】 Standard Test Method for Portland-Cement Content of Hardened Hydraulic-Cement Concrete
本网站 发布时间:
2024-02-28
开通会员免费在线看70000余条国内标准,赠送文本下载次数,单本最低仅合13.3元!还可享标准出版进度查询、定制跟踪推送、标准查新等超多特权!  
查看详情>>

适用范围:
3.1 This test method consists of two independent procedures: an oxide-analysis procedure that consists of two sub-procedures and an extraction procedure. Each procedure requires a substantial degree of chemical skill and relatively elaborate chemical instrumentation. Except for the influence of known interferences, determined cement contents are normally equal to, or slightly greater than, actual values except for the Maleic Acid procedure where results can also be significantly low when the paste is carbonated (Note 1).NOTE 1: With certain limitations, the procedure is also applicable for estimating the combined content of portland cement and pozzolan or slag in concretes made with blended hydraulic cement and blends of portland cement with pozzolans or slags. The results of this test method when applied to concretes made with blended cements or pozzolans depend on the composition of the pozzolan, the age of the concrete, the extent of reaction of the pozzolan and the fact that this test method may determine only the portland-cement component of a blended cement. The test method should be applied to determination of the blended cement content or the pozzolanic content only by use of calibration concrete samples or other information. Earlier versions of this test method can provide useful information as detailed by Hime3 and Minnick.41.1 This test method covers the determination of portland-cement content of a sample of hardened hydraulic-cement concrete.1.2 The values stated in SI units are to be regarded as standard. The values given in parentheses after SI units are provided for information only and are not considered standard.1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. Disposal of some or all of the chemicals used in this method may require adherence to EPA or other regulatory guidelines.1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
标准号:
ASTM C1084-19
标准名称:
Standard Test Method for Portland-Cement Content of Hardened Hydraulic-Cement Concrete
英文名称:
Standard Test Method for Portland-Cement Content of Hardened Hydraulic-Cement Concrete标准状态:
Active-
发布日期:
-
实施日期:
出版语种:
- 推荐标准
- AS 1012.19-1988 Methods of testing concrete Accelerated curing of concrete compression test specimens (laboratory or field) - Hot water and warm water methods
- AS 1180 (Pt 9A to 9C)-1973 Methods of test for hose made from elastomeric materials - Third Group Methods 9A, 9B, 9C
- AS 1418.19-2007 Cranes, hoists and winches Telescopic handlers
- AS 1678.3C1-1987 Emergency procedure guide - Transport Group text EPGs for Class 3 substances - Flammable liquids - Flammable liquid of lesser hazard
- AS 1684.3 C1 Supp 1-2006 Residential timber-framed construction Cyclonic areas - C1 Supplement 1: Timber framing span tables - Wind classification C1 - Seasoned softwood - Stress Grade F5 (Supplement to AS 1684.3-2006)
- AS 1684.3 C1 Supp 10-1999 Residential timber-framed construction Cyclonic areas - C1 Supplement 10: Timber framing span tables - Wind classification C1 - Unseasoned softwood - Stress Grade F5 (Supplement to AS 1684.3-1999)
- AS 1684.3 C1 Supp 11-1999 Residential timber-framed construction Cyclonic areas - C1 Supplement 11: Timber framing span tables - Wind classification C1 - Unseasoned softwood - Stress Grade F7 (Supplement to AS 1684.3-1999)
- AS 1684.3 C1 Supp 12-2010 Residential timber-framed construction Cyclonic areas - C1 Supplement 12: Timber framing span tables - Wind classification C1 - Unseasoned hardwood - Stress Grade F8 (Supplement to AS 1684.3-2010)
- AS 1684.3 C1 Supp 13-2006 Residential timber-framed construction Cyclonic areas - C1 Supplement 13: Timber framing span tables - Wind classification C1 - Unseasoned hardwood - Stress Grade F11 (Supplement to AS 1684.3-2006)
- AS 1684.3 C1 Supp 14-2006 Residential timber-framed construction Cyclonic areas - C1 Supplement 14: Timber framing span tables - Wind classification C1 - Unseasoned hardwood - Stress Grade F14 (Supplement to AS 1684.3-2006)
- AS 1684.3 C1 Supp 15-1999 Residential timber-framed construction Cyclonic areas - C1 Supplement 15: Timber framing span tables - Wind classification C1 - Unseasoned hardwood - Stress Grade F17 (Supplement to AS 1684.3-1999)
- AS 1684.3 C1 Supp 15-2006 Residential timber-framed construction Cyclonic areas - C1 Supplement 15: Timber framing span tables - Wind classification C1 - Unseasoned hardwood - Stress Grade F17 (Supplement to AS 1684.3-2006)
- AS 1684.3 C1 Supp 2-1999 Residential timber-framed construction Cyclonic areas - C1 Supplement 2: Timber framing span tables - Wind classification C1 - Seasoned softwood - Stress Grade F7 (Supplement to AS 1684.3-1999)
- AS 1684.3 C1 Supp 2-2010 Residential timber-framed construction Cyclonic areas - C1 Supplement 2: Timber framing span tables - Wind classification C1 - Seasoned softwood - Stress Grade F7 (Supplement to AS 1684.3 - 2010)
- AS 1684.3 C1 Supp 3-1999 Residential timber-framed construction Cyclonic areas - C1 Supplement 3: Timber framing span tables - Wind classification C1 - Seasoned softwood - Stress Grade F8 (Supplement to AS 1684.3-1999)