【国外标准】 Standard Practice for Design, Construction, and Material Requirements for Direct Hung Suspended T-bar Type Ceiling Systems Intended to Receive Gypsum Panel Products in Areas Subject to Earthquake Ground Motions
本网站 发布时间:
2024-02-28
开通会员免费在线看70000余条国内标准,赠送文本下载次数,单本最低仅合13.3元!还可享标准出版进度查询、定制跟踪推送、标准查新等超多特权!  
查看详情>>

适用范围:
5.1 This practice provides a standardized installation procedure for ceilings designed and installed as a diaphragm. When installed according to this practice, these ceilings have sufficient strength to resist seismic forces without lateral force bracing.1.1 This practice covers the installation requirements of direct hung suspended t-bar type ceiling systems intended to receive gypsum panel products constructed as flat, single level, surrounded on all sides by a wall, bulk head, or soffit braced to the building structure to resist the effects of earthquake ground motions.1.2 Ceiling assembly shall not be intended to support live loads.1.3 This standard addresses ceiling systems with dead loads up to 10 lbs/ft2 (48.8 kg/m2).1.4 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard.1.5 The text of this standard references notes and footnotes which provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of the standard1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
标准号:
ASTM C1858-17a(2021)
标准名称:
Standard Practice for Design, Construction, and Material Requirements for Direct Hung Suspended T-bar Type Ceiling Systems Intended to Receive Gypsum Panel Products in Areas Subject to Earthquake Ground Motions
英文名称:
Standard Practice for Design, Construction, and Material Requirements for Direct Hung Suspended T-bar Type Ceiling Systems Intended to Receive Gypsum Panel Products in Areas Subject to Earthquake Ground Motions标准状态:
Active-
发布日期:
-
实施日期:
出版语种:
- 其它标准
- 上一篇: ASTM C1857/C1857M-19 Standard Test Method for Evaluating the Adhesion (Pull-Off) Strength of Concrete Repair and Overlay Mortar
- 下一篇: ASTM C1859-23 Standard Practice for Determination of Thermal Resistance of Pneumatically Installed Loose-Fill Building Insulation (Behind Netting) for Enclosed Applications of the Building Thermal Envelope
- 推荐标准
- INCITS 103-1983 (S2021) Unrecorded Magnetic Tape Minicassette For Information Interchange, Coplanar 3.81 mm (0.150 Inch)
- INCITS 121-1984 (S2021) Two-Sided Unformatted 8-Inch (200 MM) Double Density Flexible Disk Cartridge (For 13262 FTPR Two-headed Application) (Combined with Project 287)
- INCITS 124.1-1985 (S2021) FORTRAN Binding of Graphical Kernel System (GKS)
- INCITS 125-1985 (S2021) Two-Sided, Double-Density, Unformatted 5.25 Inch (130 mm) 48-tpi (1.9 tpmm) Flexible Disk Cartridge for 7958 BPR Use
- INCITS 164-1990 (S2021) Unrecorded Magnetic Tape Cassette for Information Interchange 3.81 mm (0.150 In), 252 to 394 ftpmm (6400 to 10000 ftpi)
- INCITS 180-1990 (S2021) Magnetic Tape and Cartridge for Information Interchange, 18-Track, Parallel, 12.65mm (1/2 in.) 1491 cpmm (37 871 cpi) Group-Coded, Requirements for Recording
- INCITS 181-1990 (S2021) Recorded Magnetic Tape Cartridge for Information Interchange 0.500 in, 22 and 48 Tracks Serial Serpentine, 6 667 and 10 000 bpi
- INCITS 22-1983 (S2021) Recorded Magnetic Tape for Information Interchange (800 CPI, NRZI)
- INCITS 232-1996 (S2021) SCSI-2 Common Access Method Transport and SCSI Interface Module
- INCITS 243-1996 (S2021) Serial Magnetic Tape Cartridge for Information Interchange, 26 Tracks, 0.250 in (6.35 mm), 16 000 bpi (630 bpmm), Streaming Mode, Group Code Recording
- INCITS 248-1996 (S2021) Abstract Test Suite for FDDI Physical Layer Protocol Conformance Testing (FDDI PHY ATS)
- INCITS 250-1996 (S2021) Recorded Magnetic Tape Mini-Cartridge for Information Interchange, 0.250 in (630 mm)12 and 24 Track,10000 bpi (394 bpmm) GCR
- INCITS 269-1996 (S2021) SCSI-3 Fibre Channel Protocol (FCP)
- INCITS 282-1996 (S2021) Magnetic Tape Cartridge for Information Interchange, 0.50 in (12.65 mm) Serial Serpentine, 128-Track, 62 500 bpi (2460 bpmm), DLT3 Format
- INCITS 293-1996 (S2021) Serial Storage Architecture - Physical Layer 1 (SSA-PH1)