
【国外标准】 Standard Guide for Selection of Minimum Set of Data Elements Required to Identify Locations Chosen for Field Collection of Information to Describe Soil, Rock, and Their Contained Fluids (Withdrawn 2019)
本网站 发布时间:
2024-02-28
- ASTM D6168-97(2010)
- Withdrawn, No replacement
- 定价: 0元 / 折扣价: 0 元
- 在线阅读
开通会员免费在线看70000余条国内标准,赠送文本下载次数,单本最低仅合13.3元!还可享标准出版进度查询、定制跟踪推送、标准查新等超多特权!  
查看详情>>

适用范围:
Adequately documented geoscience data are beneficial to studies utilizing traditional and computer technology for conducting resource surveys and in analyzing environmental concerns.Geoscience data that include the standard coordinates pinpoint the location of the information on or below the earth's surface and by that establish the dimensional relationship to data of a similar nature (see 5.2).Note 6—Some investigations destroy the sample in the process. As such, the information cannot be duplicated by resampling. The data and the original location of the tested sample may be the only remaining result.Geoscience data that include “key” information has an enhanced capability for acceptable verification, as each additional data item strengthens the uniqueness for singular identification.Key data categories included for unique identification of the geoscience information consist of political regimes, source of data, and location characteristics (see 5.3).Use of a standardized minimum set of data elements by project investigators increase the usefulness of the geoscience information, in that the material can more easily be interchanged.Data verification, essential in quality control, can be more routine when geoscience locations are accurately identified.Key items allow for ease of selection by placing the geoscience data into logical categories, such as counties, resource extraction locations, and source agencies.Data files organized by use of key data elements, whether stored in cabinets or a computer file, are less complicated to find.Geoscience data are usually collected for an ongoing project, however, the value is greatly increased when these data are available for future studies.1.1 This guide covers factors to consider for the selection of the minimum set of data elements required for the accurate location and cataloging of information collected for geological science (geoscience) investigations, which includes geoecology.1.1.1 Geoscience investigations include soil surveys, foundation investigations, geologic studies, hydrologic evaluations, environmental appraisals, contamination inquiries, archaeological surveys, and other studies that involve the soil, rock, and contained fluids from the lands surface to any explored depth underground.1.2 A unique geoscience data location, on or below the earth's surface, can be described by X, Y, and Z coordinates and by that method establish the dimensional relationship to data of a similar nature. Additional location information needed depends upon the type of geoscience data collection locality.1.2.1 The basic type is a single position described by finite X, Y, and Z coordinates. The X, Y, and Z coordinates uniquely position the location on or below the earth's surface.Note 1—An example is the latitude and longitude in horizontal coordinates and the altitude (or elevation) in vertical distance of a groundwater location or site. Data collected at the site, for example, water levels, are measured by the vertical interval as referenced to the altitude.1.2.2 Another type of location is described by finite X and Y coordinates that has multiple vertically positioned Z coordinates. This is equivalent to the location type described in 1.2.1, except that multiple vertical dimensions are stated as Z coordinates, rather than vertical intervals.Note 2—An example is latitude, longitude, and multiple altitudes of a soil sampling location or site. Each altitude represents a different sampling position that has the same latitude and longitude coordinate. The upper and lower limit of a sampling interval can be expressed by altitudes.1.2.3 Another type is a location described by finite X and Y coordinates with multiple Z coordinates that are not vertically oriented from X and Y coordinates.Note 3—An example is a slanted borehole where the top is at a different latitude and longitude coordinate than the sampling positions in the hole. Methods of describing these sampling points are: treat each position as a separate location with finite latitude, longitude, and altitude values; describe the horizontal deviation of the sampling point from the finite latitude and longitude coordinates at the top of the borehole.1.2.4 Another type is a location with considerable horizontal dimension that cannot be described by a finite X and Y coordinate, however, a single Z coordinate may be acceptable.Note 4—Examples are sinkholes, waste disposal pits, septic systems, underground injection facilities, mines, archaeological sites, and some ponds or lakes. These locations can be described by including additional information that gives the horizontal components of the location along with the latitude, longitude, and altitude coordinates or by multiple sets of X and Y coordinates that encompass the location.1.3 Additional key data elements are needed to simplify the identification and cataloging of the geoscience data.1.3.1 These elements describe political entities, data sources, and individual characteristics of the location.Note 5—The data assist in file organization by placing the information into logical categories and to further identify the geoscience location by use of familiar terminology. A carefully designed minimum set of data elements contributes to the recoverability and the future value of the entire data file.1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.1.5 This guide offers an organized collection of information or a series of options and does not recommend a specific course of action. This guide cannot replace education or experience and should be used in conjunction with professional judgment. Not all aspects of this guide may be applicable in all circumstances. This guide is not intended to represent or replace the standard of care by which the adequacy of a given professional service must be judged, nor should this guide be applied without consideration of a project's many unique aspects. The word “Standard” in the title of this document means only that the document has been approved through the ASTM consensus process.
标准号:
ASTM D6168-97(2010)
标准名称:
Standard Guide for Selection of Minimum Set of Data Elements Required to Identify Locations Chosen for Field Collection of Information to Describe Soil, Rock, and Their Contained Fluids (Withdrawn 2019)
英文名称:
Standard Guide for Selection of Minimum Set of Data Elements Required to Identify Locations Chosen for Field Collection of Information to Describe Soil, Rock, and Their Contained Fluids (Withdrawn 2019)标准状态:
Withdrawn, No replacement-
发布日期:
-
实施日期:
出版语种:
- 推荐标准
- ASTM F3258-23 Standard Specification for Protectors for Rubber Insulating Gloves Meeting Specific Performance Requirements
- ASTM F3259-17 Standard Guide for Micro-computed Tomography of Tissue Engineered Scaffolds
- ASTM F3260-18 Standard Test Method for Determining the Flexural Stiffness of Medical Textiles
- ASTM F3262-17 Standard Classification System for Small Unmanned Aircraft Systems (sUASs) for Land Search and Rescue
- ASTM F3265-17(2023) Standard Test Method for Grid-Video Obstacle Measurement
- ASTM F3268-18a Standard Guide for in vitro Degradation Testing of Absorbable Metals
- ASTM F3270/F3270M-17 Standard Practice for Compression versus Load Properties of Gasket Materials
- ASTM F3273-17(2021)e1 Standard Specification for Wrought Molybdenum-47.5 Rhenium Alloy for Surgical Implants (UNS R03700)
- ASTM F3275-22 Standard Guide for Using a Force Tester to Evaluate Performance of a Brush Part Designed to Clean the Internal Channel of a Medical Device
- ASTM F3276-22 Standard Guide for Using a Force Tester to Evaluate the Performance of a Brush Part Designed to Clean the External Surface of a Medical Device
- ASTM F3277-19 Standard Specification for Cantilevered Steel Bunks Used in Detention and Correctional Facilities
- ASTM F3283/F3283M-18 Standard Specification for the Manufacturing of High-Voltage Proximity Alarm to be used for the Detection of Overhead High Voltage Alternating Current (AC)
- ASTM F3288/F3288M-20 Standard Specification for MRS-Rated Metric- and Inch-sized Crosslinked Polyethylene (PEX) Pressure Pipe
- ASTM F3292-19 Standard Practice for Inspection of Spinal Implants Undergoing Testing
- ASTM F3293-18 Standard Guide for Application of Test Soils for the Validation of Cleaning Methods for Reusable Medical Devices